Overview
A Vertical AHU (Vertical Air Handling Unit) is a floor-mounted HVAC system designed to provide efficient indoor air conditioning. It combines multiple functional sections, including air filtration, cooling, heating, and humidification, to deliver clean and comfortable air. Compared with horizontal air handling units, its upright design reduces the need for overhead installation space and offers greater flexibility in equipment placement. With its space-saving structure and versatile configuration, the Vertical AHU is widely suitable for hospitals, laboratories, cleanrooms, commercial buildings, and facilities with limited ceiling space.
|
performance |
Air volume |
Residual Pressure |
Cooling volume ( K W ) |
Heat volume ( K W ) |
Water volume(T/h) |
Water reistance(KPa) |
power |
Noice |
Weight |
||||
|
Return Air |
Fresh Air |
Return Air |
Fresh Air |
Return Air |
Fresh Air |
Return Air |
Fresh Air |
||||||
|
BFP-20W/L |
2000 |
200 |
11.2 |
22.5 |
19.1 |
28.00 |
1.9 |
3.9 |
3.5 |
4.2 |
0.32 |
55 |
140/160 |
|
BFP-20XW/L |
160 |
13.9 |
29.7 |
25.7 |
32.67 |
2.4 |
5.1 |
4.5 |
5.6 |
160/190 |
|||
|
BFP-30W/L |
3000 |
260 |
16.8 |
33.8 |
28.6 |
42.00 |
2.9 |
5.8 |
4.5 |
6.4 |
0.55 |
56 |
160/180 |
|
BFP-30XW/L |
220 |
20.8 |
44.5 |
38.5 |
49.00 |
3.6 |
7.7 |
5.3 |
8.5 |
180/210 |
|||
|
BFP-40W/L |
4000 |
340 |
22.4 |
45.1 |
38.1 |
56.00 |
3.9 |
7.7 |
4.6 |
6.7 |
0.75 |
58 |
195/220 |
|
BFP-40XW/L |
300 |
27.7 |
59.3 |
51.3 |
64.33 |
4.8 |
10.2 |
6.5 |
12.4 |
225/255 |
|||
|
BFP-45W/L |
4500 |
320 |
25.2 |
50.7 |
42.9 |
63.00 |
4.3 |
8.7 |
5.2 |
8.6 |
0.75 |
58 |
205/220 |
|
BED-45XW/ |
280 |
31.2 |
66.8 |
57.8 |
73.50 |
5.4 |
11.5 |
7.4 |
15.4 |
215/235 |
|||
|
BFP-50W/L |
5000 |
500 |
28.0 |
56.3 |
47.7 |
70.00 |
4.8 |
9.7 |
6.8 |
10.7 |
1.1 |
59 |
220/235 |
|
BFP-50XW/L |
460 |
34.7 |
74.2 |
64.2 |
81.67 |
6.0 |
12.8 |
8.1 |
19.5 |
230/255 |
|||
|
BFP-55W/L |
5500 |
500 |
30.8 |
62.0 |
52.4 |
77.00 |
5.3 |
10.7 |
6.5 |
12.7 |
1.5 |
59 |
238/256 |
|
BFP-55XW/L |
460 |
38.1 |
81.6 |
70.6 |
89.83 |
6.6 |
14.0 |
9.5 |
20.3 |
256/286 |
|||
|
BFP-60W/L |
6000 |
500 |
33.6 |
67.6 |
57.2 |
84.00 |
5.8 |
11.6 |
7.4 |
14.8 |
1.5 |
60 |
258/285 |
|
BFP-60XW/L |
460 |
41.6 |
89.0 |
77.0 |
98.00 |
7.2 |
15.3 |
11.3 |
28.2 |
285/306 |
|||
|
BFP-70W/L |
7000 |
500 |
39.2 |
78.9 |
66.7 |
98.00 |
6.7 |
13.6 |
8.5 |
16.5 |
1.8 |
61 |
282/312 |
|
BFP-70XW/L |
460 |
48.5 |
103.8 |
89.8 |
114.33 |
8.3 |
17.9 |
14.6 |
33.3 |
315/346 |
|||
|
BFP-80W/L |
8000 |
600 |
44.8 |
90.1 |
76.3 |
112.00 |
7.7 |
15.5 |
9.06 |
18.4 |
2.2 |
62 |
310/345 |
|
BFP-80XW/L |
560 |
55.5 |
118.7 |
102.7 |
130.67 |
9.5 |
20.4 |
16.4 |
39.6 |
338/369 |
|||
|
BFP-90W/L |
9000 |
600 |
50.4 |
101.4 |
85.8 |
126.00 |
8.7 |
17.4 |
10.6 |
22.4 |
2.2 |
63 |
322/358 |
|
BFP-90XW/L |
560 |
62.4 |
133.5 |
115.5 |
147.00 |
10.7 |
23.0 |
18.2 |
43.6 |
345/369 |
|||
|
BFP-100W/L |
10000 |
600 |
56.0 |
112.7 |
95.3 |
140.00 |
9.6 |
19.4 |
12.4 |
26.7 |
3.0 |
64 |
336/368 |
|
BFP-100XW/L |
560 |
69.3 |
148.3 |
128.3 |
163.33 |
11.9 |
25.5 |
21.6 |
48.6 |
356/389 |
|||
|
BFP-120W/L |
12000 |
600 |
67.2 |
135.2 |
114.4 |
168.00 |
11.6 |
23.2 |
18.7 |
40.1 |
1.8×2 |
64 |
438/475 |
|
BFP-120XW/L |
560 |
83.2 |
178.0 |
154.0 |
196.00 |
14.3 |
30.6 |
28.4 |
53.2 |
476/506 |
|||
|
BFP-150W/L |
15000 |
600 |
84.0 |
169.0 |
143.0 |
210.00 |
14.4 |
29.1 |
22.6 |
42.6 |
2.2×2 |
64 |
520/550 |
|
BFP-150XW/L |
560 |
104.0 |
222.5 |
192.5 |
245.00 |
17.9 |
38.3 |
35.7 |
73.5 |
562/598 |
|||
|
BFP-180W/L |
18000 |
600 |
1008 |
202.8 |
171.6 |
252.00 |
17.3 |
34.9 |
25.1 |
44.2 |
3.0×2 |
65 |
556/581 |
|
BFP-180XW/L |
560 |
124.8 |
267.0 |
231.0 |
294.00 |
21.5 |
45.9 |
47.6 |
78.2 |
585/615 |
|||
|
BFP-200W/L |
20000 |
600 |
112.0 |
225.3 |
190.7 |
280.00 |
19.3 |
38.7 |
28.7 |
46.5 |
3.0×2 |
65 |
576/595 |
|
BFP-200XW/L |
560 |
138.7 |
296.7 |
256.7 |
326.67 |
23.8 |
51.0 |
51.6 |
82.6 |
610/638 |
|||
|
BFP-230W/L |
23000 |
650 |
1288 |
259.1 |
219.3 |
322.00 |
22.1 |
44.6 |
29.7 |
48.7 |
4.0×2 |
68 |
612/635 |
|
BFP-230XW/L |
600 |
159.5 |
341.2 |
295.2 |
375.67 |
27.4 |
58.7 |
51.6 |
85.2 |
639/672 |
|||
|
BFP-250W/L |
25000 |
650 |
140.0 |
281.7 |
238.3 |
350.00 |
24.1 |
48.4 |
26.5 |
49.6 |
4.0×2 |
69 |
652/685 |
|
BFP-250XW/L |
600 |
173.3 |
370.8 |
320.8 |
408.33 |
29.8 |
63.8 |
50.2 |
82.6 |
710/732 |
|||
|
BFP-280W/L |
28000 |
650 |
156.8 |
315.5 |
266.9 |
39200 |
27.0 |
54.2 |
32.6 |
43.6 |
5.5×2 |
70 |
679/712 |
|
BFP-280XW/L |
600 |
194.1 |
415.3 |
359.3 |
457.33 |
33.4 |
71.4 |
54.5 |
92.5 |
729/758 |
|||
|
BFP-300W/L |
30000 |
650 |
168.0 |
338.0 |
286.0 |
420.00 |
28.9 |
58.1 |
36.9 |
52.3 |
5.5×2 |
70 |
712/735 |
|
BFP-300XW/L |
600 |
208.0 |
445.0 |
385.0 |
490.00 |
35.8 |
76.5 |
57.2 |
91.2 |
765/796 |
|||
|
BFP-350W/L |
35000 |
650 |
196.0 |
394.3 |
333.7 |
490.00 |
33.7 |
67.8 |
38.7 |
59.4 |
7.5×2 |
72 |
826/998 |
|
BFP-350XW/L |
600 |
242.7 |
519.2 |
449.2 |
571.67 |
41.7 |
89.3 |
58.7 |
96.2 |
910/1110 |
|||
Return Air Conditions:
-
Cooling Mode: Return air inlet condition: 27°C dry‑bulb, 19.5°C wet‑bulb. Chilled water supply temperature: 7°C, water temperature rise across coil: 5 K.
Heating Mode: Return air inlet dry‑bulb temperature: 15°C. Hot water supply temperature: 60°C.
Fresh Air Operating Conditions
Cooling Mode: Fresh air inlet condition: 34°C dry‑bulb, 28°C wet‑bulb. Chilled water supply temperature: 7°C, water temperature rise across coil: 5 K.
Heating Mode: Fresh air inlet dry‑bulb temperature: -4°C. Hot water supply temperature: 60°C.
Key Features
● Direct Expansion Cooling and Heating
Equipped with a DX coil, the system uses refrigerant to transfer heat directly between the air and the coil. It provides both cooling and heating without relying on chilled water circulation.
● No Chilled Water Infrastructure Required
The DX system eliminates the need for chillers, cooling towers, and complex water pipe networks. Its simplified configuration helps reduce installation costs and routine maintenance requirements.
● Flexible and Space-Efficient Installation
With a compact structure, DX AHUs are suitable for renovation projects and buildings with limited equipment space. They are commonly connected to an outdoor condensing unit to complete the refrigeration cycle.
● Rapid Temperature Adjustment
Direct refrigerant heat exchange enables quick responses to indoor temperature changes, helping maintain a comfortable environment with efficient cooling and heating performance.
● Independent Zone Temperature Control
Multiple DX air handling units can operate in different areas, allowing each zone to adjust its temperature independently according to specific comfort and operational requirements.
Applications
● Commercial Applications – Suitable for office buildings, shopping malls, hotels, restaurants, and other commercial spaces requiring reliable air conditioning.
● Residential Applications – Ideal for apartments, private residences, condominiums, and multi-family housing projects.
● Industrial & Data Center Applications – Provides stable temperature regulation and dependable climate control for industrial facilities, server rooms, and data centers.
● Healthcare & Educational Applications – Supports comfortable indoor environments in hospitals, clinics, schools, and universities through effective air distribution and indoor air quality management.




FAQ
Q: Can products be produced according to customer requirements?
Q: Is it allowed to visit the factory?
Q: Are you looking for agents?
Q: How do you resolve issues if there are malfunctions during the use of the equipment?
Q: What software do you use for your product drawings?
Hot Tags: vertical ahu, China vertical ahu manufacturers, suppliers, factory, air handling unit filters, air handling unit manuals, air handling unit pressure sensors, air handling unit suppliers, air handling unit with direct expansion, commercial air handling unit