Ahu With Dx Coil
Ahu With Dx Coil

Ahu With Dx Coil

A Horizontal Air Handling Unit (AHU) is an HVAC equipment designed for horizontal installation with airflow moving horizontally through the unit. It integrates all essential air handling functions such as heating, cooling, humidification, dehumidification, and air filtration. This design is ideal for buildings where space-saving or optimized installation layout is required.
Send Inquiry
Overview

 

Air Handling Unit (AHU) with a Direct Expansion (DX) Coil is a type of HVAC system designed to condition and distribute air efficiently in commercial, industrial, and residential buildings. Unlike traditional AHUs that use chilled water for cooling, AHUs with DX coils use refrigerant to directly cool the air before it is distributed through the duct system. This system is commonly used in spaces where a chilled water system is impractical or unnecessary.

 

performance


Model

Air volume

(m³/h)

Residual Pressure

(Pa)

Cooling volume ( K W )

Heat volume ( K W )

Water volume(T/h)

Water reistance(KPa)

power

(KW)

Noice

dB(A)

Weight

(kg)

Return Air

Fresh Air

Return Air

Fresh Air

Return Air

Fresh Air

Return Air

Fresh Air

BFP-20W/L

2000

200

11.2

22.5

19.1

28.00

1.9

3.9

3.5

4.2

0.32

55

140/160

BFP-20XW/L

160

13.9

29.7

25.7

32.67

2.4

5.1

4.5

5.6

160/190

BFP-30W/L

3000

260

16.8

33.8

28.6

42.00

2.9

5.8

4.5

6.4

0.55

56

160/180

BFP-30XW/L

220

20.8

44.5

38.5

49.00

3.6

7.7

5.3

8.5

180/210

BFP-40W/L

4000

340

22.4

45.1

38.1

56.00

3.9

7.7

4.6

6.7

0.75

58

195/220

BFP-40XW/L

300

27.7

59.3

51.3

64.33

4.8

10.2

6.5

12.4

225/255

BFP-45W/L

4500

320

25.2

50.7

42.9

63.00

4.3

8.7

5.2

8.6

0.75

58

205/220

BED-45XW/

280

31.2

66.8

57.8

73.50

5.4

11.5

7.4

15.4

215/235

BFP-50W/L

5000

500

28.0

56.3

47.7

70.00

4.8

9.7

6.8

10.7

1.1

59

220/235

BFP-50XW/L

460

34.7

74.2

64.2

81.67

6.0

12.8

8.1

19.5

230/255

BFP-55W/L

5500

500

30.8

62.0

52.4

77.00

5.3

10.7

6.5

12.7

1.5

59

238/256

BFP-55XW/L

460

38.1

81.6

70.6

89.83

6.6

14.0

9.5

20.3

256/286

BFP-60W/L

6000

500

33.6

67.6

57.2

84.00

5.8

11.6

7.4

14.8

1.5

60

258/285

BFP-60XW/L

460

41.6

89.0

77.0

98.00

7.2

15.3

11.3

28.2

285/306

BFP-70W/L

7000

500

39.2

78.9

66.7

98.00

6.7

13.6

8.5

16.5

1.8

61

282/312

BFP-70XW/L

460

48.5

103.8

89.8

114.33

8.3

17.9

14.6

33.3

315/346

BFP-80W/L

8000

600

44.8

90.1

76.3

112.00

7.7

15.5

9.06

18.4

2.2

62

310/345

BFP-80XW/L

560

55.5

118.7

102.7

130.67

9.5

20.4

16.4

39.6

338/369

BFP-90W/L

9000

600

50.4

101.4

85.8

126.00

8.7

17.4

10.6

22.4

2.2

63

322/358

BFP-90XW/L

560

62.4

133.5

115.5

147.00

10.7

23.0

18.2

43.6

345/369

BFP-100W/L

10000

600

56.0

112.7

95.3

140.00

9.6

19.4

12.4

26.7

3.0

64

336/368

BFP-100XW/L

560

69.3

148.3

128.3

163.33

11.9

25.5

21.6

48.6

356/389

BFP-120W/L

12000

600

67.2

135.2

114.4

168.00

11.6

23.2

18.7

40.1

1.8×2

64

438/475

BFP-120XW/L

560

83.2

178.0

154.0

196.00

14.3

30.6

28.4

53.2

476/506

BFP-150W/L

15000

600

84.0

169.0

143.0

210.00

14.4

29.1

22.6

42.6

2.2×2

64

520/550

BFP-150XW/L

560

104.0

222.5

192.5

245.00

17.9

38.3

35.7

73.5

562/598

BFP-180W/L

18000

600

1008

202.8

171.6

252.00

17.3

34.9

25.1

44.2

3.0×2

65

556/581

BFP-180XW/L

560

124.8

267.0

231.0

294.00

21.5

45.9

47.6

78.2

585/615

BFP-200W/L

20000

600

112.0

225.3

190.7

280.00

19.3

38.7

28.7

46.5

3.0×2

65

576/595

BFP-200XW/L

560

138.7

296.7

256.7

326.67

23.8

51.0

51.6

82.6

610/638

BFP-230W/L

23000

650

1288

259.1

219.3

322.00

22.1

44.6

29.7

48.7

4.0×2

68

612/635

BFP-230XW/L

600

159.5

341.2

295.2

375.67

27.4

58.7

51.6

85.2

639/672

BFP-250W/L

25000

650

140.0

281.7

238.3

350.00

24.1

48.4

26.5

49.6

4.0×2

69

652/685

BFP-250XW/L

600

173.3

370.8

320.8

408.33

29.8

63.8

50.2

82.6

710/732

BFP-280W/L

28000

650

156.8

315.5

266.9

39200

27.0

54.2

32.6

43.6

5.5×2

70

679/712

BFP-280XW/L

600

194.1

415.3

359.3

457.33

33.4

71.4

54.5

92.5

729/758

BFP-300W/L

30000

650

168.0

338.0

286.0

420.00

28.9

58.1

36.9

52.3

5.5×2

70

712/735

BFP-300XW/L

600

208.0

445.0

385.0

490.00

35.8

76.5

57.2

91.2

765/796

BFP-350W/L

35000

650

196.0

394.3

333.7

490.00

33.7

67.8

38.7

59.4

7.5×2

72

826/998

BFP-350XW/L

600

242.7

519.2

449.2

571.67

41.7

89.3

58.7

96.2

910/1110

 

Return Air Conditions:

  • Cooling: Inlet air dry-bulb temperature is 27°C, wet-bulb temperature is 19.5°C; inlet water temperature is 7°C with a water temperature difference of 5°C between inlet and outlet.
  • Heating: Inlet air dry-bulb temperature is 15°C; hot water inlet temperature is 60°C.

 

Fresh Air Conditions:

  • Cooling: Inlet air dry-bulb temperature is 34°C, wet-bulb temperature is 28°C; inlet water temperature is 7°C with a water temperature difference of 5°C between inlet and outlet.
  • Heating: Inlet air dry-bulb temperature is -4°C; hot water inlet temperature is 60°C.

 

Key Features

 

 Air Handling Unit (AHU)

Houses the major components, including filters, fans, dampers, and coils.

Distributes conditioned air throughout the duct system.

 DX Cooling Coil

The DX coil contains refrigerant that absorbs heat directly from the air.

The heat exchange process cools the air before it is distributed.

 Compressor

The heart of the DX system, responsible for compressing and circulating the refrigerant through the system.

Located in the condensing unit, which is usually installed outdoors.

 Expansion Valve

Regulates the flow of refrigerant into the DX coil.

Ensures that the refrigerant enters in a low-pressure, low-temperature state for optimal cooling.

  Condenser

Located in the outdoor condensing unit, where the refrigerant releases absorbed heat.

Uses air-cooled or water-cooled technology to remove heat from the refrigerant.

 Evaporator Fan

Draws warm air from the building over the DX coil.

The air is cooled and then pushed into the supply duct system.

 Filters

Trap dust, debris, and contaminants before air enters the cooling coil.

Improve indoor air quality and protect the AHU components.

 

Applications

 Commercial Buildings

Offices, malls, and hotels where centralized cooling is needed without a complex chilled water system.

 Industrial Facilities

Used in factories and production areas where cooling is required for both human comfort and machinery operation.

 Healthcare Facilities

Hospitals and laboratories require precise temperature and humidity control.

 Data Centers

Critical for cooling IT equipment and maintaining optimal server performance.

 Educational Institutions

Schools, universities, and training centers benefit from energy-efficient cooling solutions.

 Residential Complexes

Apartment buildings and high-rise residential structures where centralized air conditioning is needed.

22 2

.jpg

(1).jpg

 

 

product-907-456

 

 

 

FAQ

 

Q: Can products be produced according to customer requirements?

A: Yes, the specifications mentioned above are standard, and we can design and manufacture according to your requirements.

Q: Is it allowed to visit the factory?

A: Yes, we welcome customers to visit our factory.

Q: Are you looking for agents?

A: Yes, we are looking for agents worldwide. Please contact us for further discussion.

Q: How do you resolve issues if there are malfunctions during the use of the equipment?

A: Please send us pictures or a video of the issue via email, and we will find and resolve the problem. If there is damage, we will send you new parts for free within the warranty period.

Q: What software do you use for your product drawings?

A: We use advanced industrial valve design and development software, such as AutoCAD.

Hot Tags: ahu with dx coil, China ahu with dx coil manufacturers, suppliers, factory, Ceiling Fan Coil Unit, Exposed Horizontal Fan Coil Unit, Desiccant Dehumidification Unit, floor convector, Hydronic Floor Convector, Modular Floor Convector