Overview
heat pump and air handler are often paired together in HVAC systems to provide both heating and cooling to a building. The heat pump acts as the primary unit for regulating the temperature by extracting or releasing heat from or to the outside air (or ground, in the case of geothermal heat pumps), while the air handler is responsible for distributing the conditioned air throughout the building. Together, they provide year-round comfort in both residential and commercial applications.
Parameter
|
Air Volume
|
Residual pressure |
Cooling(KW) |
Heat ( K W) |
Water Volume (T/h) |
Water Resistance(KPa) |
Power |
Noise |
Weight |
|||||
|
Return Air |
Fresh Air |
Return Air |
Fresh Air |
Return Air |
Fresh Air |
Return Air |
Fresh Air |
||||||
|
BFP-20W/L |
2000 |
200 |
11.2 |
22.5 |
19.1 |
28.00 |
1.9 |
3.9 |
3.5 |
4.2 |
0.32 |
55 |
140/160 |
|
BFP-20XW/L |
160 |
13.9 |
29.7 |
25.7 |
32.67 |
2.4 |
5.1 |
4.5 |
5.6 |
160/190 |
|||
|
BFP-30W/L |
3000 |
260 |
16.8 |
33.8 |
28.6 |
42.00 |
2.9 |
5.8 |
4.5 |
6.4 |
0.55 |
56 |
160/180 |
|
BFP-30XW/L |
220 |
20.8 |
44.5 |
38.5 |
49.00 |
3.6 |
7.7 |
5.3 |
8.5 |
180/210 |
|||
|
BFP-40W/L |
4000 |
340 |
22.4 |
45.1 |
38.1 |
56.00 |
3.9 |
7.7 |
4.6 |
6.7 |
0.75 |
58 |
195/220 |
|
BFP.40XW/ |
300 |
27.7 |
59.3 |
513 |
64.33 |
4.8 |
10.2 |
6.5 |
12.4 |
225/255 |
|||
|
BFP-45W/L |
4500 |
320 |
25.2 |
50.7 |
42.9 |
63.00 |
4.3 |
8.7 |
5.2 |
8.6 |
0.75 |
58 |
205/220 |
|
BFP-45XW/L |
280 |
31.2 |
66.8 |
57.8 |
73.50 |
5.4 |
11.5 |
7.4 |
15.4 |
215/235 |
|||
|
BFP-50W/L |
5000 |
500 |
28.0 |
56.3 |
47.7 |
70.00 |
4.8 |
9.7 |
6.8 |
10.7 |
1.1 |
59 |
220/235 |
|
BFP-50XW/L |
460 |
34.7 |
74.2 |
64.2 |
81.67 |
6.0 |
12.8 |
8.1 |
19.5 |
230/255 |
|||
|
BFP-55W/L |
5500 |
500 |
30.8 |
62.0 |
52.4 |
77.00 |
5.3 |
10.7 |
6.5 |
12.7 |
1.5 |
59 |
238/256 |
|
BFP-55XW/L |
460 |
38.1 |
81.6 |
70.6 |
89.83 |
6.6 |
14.0 |
9.5 |
20.3 |
256/286 |
|||
|
BFP-60W/L |
6000 |
500 |
33.6 |
67.6 |
57.2 |
84.00 |
5.8 |
11.6 |
7.4 |
14.8 |
1.5 |
60 |
258/285 |
|
BFP-60XW/L |
460 |
41.6 |
89.0 |
77.0 |
98.00 |
7.2 |
15.3 |
11.3 |
28.2 |
285/306 |
|||
|
BFP-70W/L |
7000 |
500 |
39.2 |
78.9 |
66.7 |
98.00 |
6.7 |
13.6 |
8.5 |
16.5 |
1.8 |
61 |
282/312 |
|
BFP-70XW/L |
460 |
48.5 |
103.8 |
89.8 |
114.33 |
8.3 |
17.9 |
14.6 |
33.3 |
315/346 |
|||
|
BFP-80W/L |
8000 |
600 |
44.8 |
90.1 |
76.3 |
112.00 |
7.7 |
15.5 |
9.06 |
18.4 |
2.2 |
62 |
310/345 |
|
BFP-80XW/L |
560 |
55.5 |
118.7 |
102.7 |
130.67 |
9.5 |
20.4 |
16.4 |
39.6 |
338/369 |
|||
|
BFP-90W/L |
9000 |
600 |
50.4 |
101.4 |
85.8 |
126.00 |
8.7 |
17.4 |
10.6 |
22.4 |
2.2 |
63 |
322/358 |
|
BFP-90XW/L |
560 |
62.4 |
133.5 |
115.5 |
147.00 |
10.7 |
23.0 |
18.2 |
43.6 |
345/369 |
|||
|
BFP-100W/L |
10000 |
600 |
56.0 |
112.7 |
95.3 |
140.00 |
9.6 |
19.4 |
12.4 |
26.7 |
3.0 |
64 |
336/368 |
|
BFP-100XW/L |
560 |
69.3 |
148.3 |
128.3 |
163.33 |
11.9 |
25.5 |
21.6 |
48.6 |
356/389 |
|||
|
BFP-120W/L |
12000 |
600 |
67.2 |
135.2 |
114.4 |
168.00 |
11.6 |
23.2 |
18.7 |
40.1 |
1.8×2 |
64 |
438/475 |
|
BFP-120XW/L |
560 |
83.2 |
178.0 |
154.0 |
196.00 |
14.3 |
30.6 |
28.4 |
53.2 |
476/506 |
|||
|
BFP-150W/L |
15000 |
600 |
84.0 |
169.0 |
143.0 |
210.00 |
14.4 |
29.1 |
22.6 |
42.6 |
2.2×2 |
64 |
520/55 |
|
BFP-150XW/L |
560 |
104.0 |
222.5 |
192.5 |
245.00 |
17.9 |
38.3 |
35.7 |
73.5 |
562/598 |
|||
|
BFP-180W/L |
18000 |
600 |
100.8 |
202.8 |
171.6 |
252.00 |
17.3 |
34.9 |
25.1 |
44.2 |
3.0×2 |
65 |
556/581 |
|
BFP-180XW/L |
560 |
124.8 |
267.0 |
231.0 |
294.00 |
21.5 |
45.9 |
47.6 |
78.2 |
585/615 |
|||
|
BFP-200W/L |
20000 |
600 |
112.0 |
225.3 |
190.7 |
280.00 |
19.3 |
38.7 |
28.7 |
46.5 |
3.0×2 |
65 |
576/595 |
|
BFP-200XW/L |
560 |
138.7 |
296.7 |
256.7 |
326.67 |
23.8 |
51.0 |
51.6 |
82.6 |
610/638 |
|||
|
BFP-230W/L |
23000 |
650 |
128.8 |
259.1 |
219.3 |
322.00 |
22.1 |
44.6 |
29.7 |
48.7 |
4.0×2 |
68 |
612/635 |
|
BFP-230XWL |
600 |
159.5 |
341.2 |
295.2 |
375.67 |
27.4 |
58.7 |
51.6 |
85.2 |
639/672 |
|||
|
BFP-250W/ |
25000 |
650 |
140.0 |
281.7 |
238.3 |
350.00 |
24.1 |
48.4 |
26.5 |
49.6 |
4.0×2 |
69 |
652/685 |
|
BFP-250XW/L |
600 |
173.3 |
370.8 |
320.8 |
408.33 |
29.8 |
63.8 |
50.2 |
82.6 |
710/732 |
|||
|
BFP-280W/L |
28000 |
650 |
156.8 |
315.5 |
266.9 |
392.00 |
27.0 |
54.2 |
32.6 |
43.6 |
5.5×2 |
70 |
679/712 |
|
BFP-280XW/L |
600 |
194.1 |
415.3 |
359.3 |
457.33 |
33.4 |
71.4 |
54.5 |
92.5 |
729/758 |
|||
|
BFP-300W/L |
30000 |
650 |
168.0 |
338.0 |
286.0 |
420.00 |
28.9 |
58.1 |
36.9 |
52.3 |
5.5×2 |
70 |
712/735 |
|
BFP-300XW/L |
600 |
208.0 |
445.0 |
385.0 |
490.00 |
35.8 |
76.5 |
57.2 |
91.2 |
765/796 |
|||
|
BFP-350W/ |
35000 |
650 |
196.0 |
394.3 |
333.7 |
490.00 |
33.7 |
67.8 |
38.7 |
59.4 |
7.5×2 |
72 |
826/998 |
|
BFP-350XW/L |
600 |
242.7 |
519.2 |
449.2 |
571.67 |
41.7 |
89.3 |
58.7 |
96.2 |
910/1110 |
|||
Key Features of Heat Pump and Air Handler
●Fan:
The fan blows air across the coils and into the duct system, ensuring proper air circulation. Fan speed can vary depending on the model, and some systems use variable-speed fans for energy efficiency.
●Coils:
Air handlers typically have heating coils (for heat pumps or electric heat) and cooling coils (for cooling). In a heat pump system, these coils work in conjunction with the heat pump to either heat or cool the air.
The refrigerant from the heat pump flows through these coils, exchanging heat with the air passing over them.
●Filters:
Air filters are integrated into the air handler to capture dust, dirt, and other particulates from the air. This improves indoor air quality by preventing contaminants from entering the HVAC system.
●Controls:
Air handlers typically have thermostats and control boards that help manage the flow of air, temperature settings, and system operation, ensuring that the space remains comfortable.
●Drain Pan/Drainage System:
In cooling mode, condensation can form on the coils. A drain pan and drainage system remove this moisture, preventing water damage and mold growth.
Applications of Heat Pump and Air Handler
●Energy Efficiency:
Heat pumps use electricity to transfer heat rather than generate it, making them more efficient than traditional heating methods. This results in lower energy consumption and cost savings over time.
●Year-Round Comfort:
The heat pump provides both heating and cooling, eliminating the need for separate systems. This versatility makes it ideal for areas with moderate climates where both heating and cooling are needed.
●Environmentally Friendly:
Heat pumps are more environmentally friendly than combustion-based heating systems, as they do not burn fossil fuels and produce fewer greenhouse gas emissions.
●Zoning Capabilities:
Systems can be set up to allow for zoning, so individual rooms or areas can have their own temperature control, improving both comfort and energy efficiency.
●Quiet Operation:
Heat pumps, especially when paired with modern air handlers with variable-speed fans, tend to be quieter than traditional HVAC systems, making them suitable for noise-sensitive environments.




FAQ
Q: Question:How is your product packaging?
Q: Can you arrange shipment for customers?
Q: If I Place A Large Order, Can I Get A Discount?
Q: Do you accept custom size designs?
Q: Can you print our company's logo on nameplates and packaging?
Hot Tags: heat pump and air handler, China heat pump and air handler manufacturers, suppliers, factory, luxury commodities, impressive items, sturdy items, reliable items, practical products, latest items


