Overview
Commercial Air Handling Unit (AHU) is a vital component of heating, ventilation, and air conditioning (HVAC) systems designed specifically for commercial buildings. Its primary function is to regulate and circulate air, ensuring optimal indoor air quality and comfort for occupants.
Parameter
Cooling, water volume, water resistance
Cooling conditions: Inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃, inlet water temperature 7℃, outlet water temperature 12℃
|
Model |
Two-row pipe |
Four-row pipe |
six-row pipe |
eight-row pipe |
||||||||
|
cooling(KW |
Water volume(m³/h) |
Water resistance (KPa) |
cooling(KW) |
Water volume (m h) |
Water resistance (KPa) |
cooling(kW) |
Water volume (m³/h) |
Water resistance (KPa) |
cooling (KW |
Water volume (m³/h) |
Water resistance (KPa) |
|
|
ZK-05 |
18.8 |
3.23 |
10.1 |
29.4 |
5.01 |
9.76 |
37.8 |
6.49 |
16.99 |
45.7 |
7.85 |
10.44 |
|
ZK-10 |
34.7 |
5.89 |
10.5 |
58.6 |
10.35 |
11.65 |
75.4 |
12.96 |
10.08 |
91.2 |
15.70 |
12.82 |
|
ZK-15 |
53.4 |
9.16 |
9.8 |
87.9 |
15.08 |
7.21 |
113.1 |
19.5 |
12.11 |
136.8 |
23.52 |
15.12 |
|
ZK-20 |
70.6 |
12.14 |
9.8 |
117.3 |
20.16 |
8.25 |
150.8 |
26.21 |
14.07 |
182.4 |
31.96 |
17.48 |
|
ZK-25 |
92.9 |
15.83 |
11.6 |
146.1 |
25.12 |
10.24 |
188.1 |
33.90 |
11.77 |
227.5 |
39.11 |
14.76 |
|
ZK-30 |
113.6 |
19.2 |
11.8 |
175.2 |
30.12 |
11.16 |
225.6 |
38.90 |
13.10 |
273.4 |
47.00 |
16.28 |
|
ZK-40 |
144.4 |
24.82 |
12.4 |
232.8 |
40.03 |
12.93 |
300.2 |
51.61 |
15.73 |
362.2 |
62.27 |
19.20 |
|
ZK-50 |
180.5 |
30.61 |
10.4 |
292.3 |
50.25 |
7.47 |
375.3 |
64.52 |
17.00 |
435.80 |
74.93 |
15.70 |
|
ZK-60 |
216.6 |
37.24 |
9.4 |
349.2 |
60.04 |
7.47 |
450.3 |
77.42 |
17.00 |
544.80 |
93.67 |
15.70 |
|
ZK-80 |
287.2 |
49.1 |
9.1 |
464.6 |
79.88 |
8.5 |
598.4 |
102.89 |
19.5 |
724.8 |
124.62 |
17.9 |
|
ZK-100 |
357.0 |
61.38 |
9.5 |
578.2 |
99.41 |
8.5 |
746.5 |
128.35 |
19.5 |
904.2 |
155.46 |
17.9 |
|
ZK-120 |
428.4 |
73.65 |
9.5 |
693.6 |
118.91 |
8.5 |
895.2 |
153.91 |
19.5 |
1084.8 |
186.51 |
17.9 |
|
ZK-160 |
591.2 |
101.65 |
11.2 |
921.6 |
158.48 |
10.3 |
1190.4 |
204.67 |
20.1 |
1443.2 |
255.93 |
32.4 |
|
ZK-200 |
740.1 |
127.25 |
12.8 |
1152.2 |
199.3 |
13.1 |
1488.1 |
255.86 |
26.4 |
1804.3 |
310.22 |
42.4 |
Note: The performance parameters of the unit at a headwind speed of 2.5m/s
Key Features of Commercial AHUs
- Customization Options:Commercial AHUs come in various sizes and configurations to meet the specific needs of different commercial spaces, such as offices, retail stores, restaurants, and hotels.
- Air Filtration and Purification:These units are equipped with advanced filtration systems to remove dust, allergens, and pollutants from the air, ensuring a clean and healthy indoor environment.
- Temperature and Humidity Control:Commercial AHUs are designed to provide precise control over temperature and humidity levels, creating a comfortable atmosphere for building occupants regardless of external weather conditions.
- Energy Efficiency:Many commercial AHUs are built with energy-efficient components and features, such as variable-speed fans, heat recovery systems, and programmable controls, to minimize energy consumption and reduce operating costs.
- Quiet Operation:Noise reduction features are incorporated into commercial AHUs to ensure quiet operation, making them suitable for use in noise-sensitive environments like offices and conference rooms.
- Reliability and Durability:Commercial AHUs are constructed with high-quality materials and undergo rigorous testing to ensure reliability and durability, providing long-lasting performance even under heavy usage.
- Integration with Building Management Systems (BMS):These units can be seamlessly integrated with building automation and management systems to enable centralized control and monitoring of HVAC operations, optimizing efficiency and performance.
Applications of Commercial AHUs
- Office Buildings: Provide climate control and ventilation for offices, meeting rooms, and common areas.
- Retail Stores: Maintain comfortable indoor environments for customers and employees.
- Restaurants: Ensure proper ventilation and air quality in dining areas and kitchens.
- Hotels: Deliver heating, cooling, and fresh air supply to guest rooms, lobbies, and other facilities.
- Healthcare Facilities: Control air quality and infection control in hospitals, clinics, and medical offices.
Blower:Blower bearings use lubricated precision ball bearings, and the outer seal ring of the bearing is made of polyamide rubber, which is resistant to high temperatures and can absorb vibration and mechanism noise. The impeller of the purification series air conditioner fan is made of high-quality steel plate (backward-inclined impeller is configured as required), which is more in line with the specific shape of aerodynamics, with high efficiency and low noise.

Surface cooler: The copper tube and aluminum sheet structure is adopted. The copper tube and aluminum sheet are tightly combimechanical or water pressure expansion, and tested by 1.6Mpa air pressure to ensure the minimum contact thermal resistance to achieve the best heat transfer effect. The condensate tray is made of high-quality steel plate or SUS304, double-layer filled with polyurethane foam, and the slope design is more conducive to the discharge of condensate, which has obtained the national patent





FAQ
Q: If I want to visit your company, which is the nearest airport?
Q: When can I get the quotation?
Q: How to place an order?
Q: What are your delivery terms?
Q: What are your payment methods?
2,Design Manufacturing) and OEM (Original Equipment Manufacturing) orders: We require a 30% deposit and the remaining 70% as the balance payment.
Hot Tags: Commercial Air Handling Unit, China Commercial Air Handling Unit manufacturers, suppliers, factory, Hospital Air Handing Unit, combined air handling unit, Commercial Air Handing Unit, Modular Air Handling Unit, Packaged Air Handling Unit, Fresh Air Ventilation Unit