Heating & Cooling Floor Convector
Heating & Cooling Floor Convector

Heating & Cooling Floor Convector

Like the forced heat-only floor embedded convector, the Heating & Cooling Floor Convector provides filtered, heated and cooled air to the building in a "stealth" way through the convection heat exchange equipment concealed in the ground trench, which can provide heating and cooling, and is beautiful and space-saving. The heat exchange element used in the dual-purpose floor embedded convector is the surface cooler. This floor convector can be arranged in units or in a continuous manner.
Send Inquiry
Overview

 

Like the forced heat-only floor embedded convector, the Heating & Cooling Floor Convector provides filtered, heated and cooled air to the building in a "stealth" way through the convection heat exchange equipment concealed in the ground trench, which can provide heating and cooling, and is beautiful and space-saving. The heat exchange element used in the dual-purpose floor embedded convector is the surface cooler. This floor convector can be arranged in units or in a continuous manner.

 

Parameter

 

AHK340/150 Double pipe type

Model

AHK340/150-1250

AHK340/150-2000

AHK340/150-2750

Speed level

3

2

1

3

2

1

3

2

1

Air flowm³h

287

197

105

574

394

210

861

591

315

Sound pressure level dB(A)

37

25

20

39

27

21

40

28

22

Power level(W

46

32

18

92

64

36

138

96

54

Number of motors

1

2

3

Water temperature(c

room temperature(C)

Heating capacity(W)

Heating capacity(W

Heating capacity(W)

95/70

18

4949

3575

2548

9713

7014

4997

14427

10390

7403

20

4796

3464

2470

5412

6796

4842

13980

10067

7173

80/60

18

3990

2882

2055

7830

5654

4028

11630

8375

5967

20

3837

2771

1976

7529

5436

3874

11183

8053

5738

75/60

18

3798

2743

1956

7454

5382

3835

11070

7972

5680

20

3644

2633

1877

7152

5164

3679

10623

7650

5450

70/55

18

3415

2466

1758

6701

4838

3447

9951

7167

5107

20

3261

2355

1679

6399

4621

3292

9504

6845

4877

60/45

18

2647

1912

1363

5194

3750

2672

7715

5556

3958

20

2493

1801

1283

4892

3533

2517

7268

5234

3729

Water temperature(℃)

room temperature(C)

Heating capacity(w)

Heating capacity(W

Heating capacity(W)

6/12

26

Qk

1434

1036

739

2814

2032

1448

4180

3010

2145

Qs

1205

870

621

2364

1707

1217

3512

2529

1802

24

Qk

1121

809

577

2198

1587

1131

3264

2351

1675

Qs

1084

783

558

2127

1536

1094

3159

2275

1621

8/14

26

Qk

1084

783

558

2127

1536

1094

3159

2275

1621

Qs

1084

783

558

2127

1536

1094

3159

2275

1621

24

Qk

873

630

449

'712

1237

881

2543

1832

1305

Qs

873

630

449

712

1237

881

2543

1832

1305

10/15

26

Qk

890

644

459

.747

1262

899

2595

1868

1331

Qs

890

644

459

747

1262

899

2595

1868

1331

24

Qk

764

552

393

-499

1082

771

2226

1603

1142

Qs

764

552

393

1499

1082

771

2226

1603

1142

12/16

26

Qk

782

565

403

535

1108

789

2279

1641

1169

Qs

782

565

403

1535

1108

789

2279

1641

1169

24

Qk

659

476

339

292

933

665

1919

1382

985

Qs

749

476

339

292

933

665

1919

1382

985

16/18

26

Qk

576

417

297

130

816

582

1679

1210

862

Qs

576

417

297

1130

816

582

1679

1210

862

24

Qk

469

338

241

920

664

473

366

984

701

Qs

469

338

241

920

664

473

1366

984

701

The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity

 

AHK340/150 four pipe type

Model

AHK340/150-1250

AHK340/150-2000

AHK340/150-2750

Speed level

3

2

1

3

2

1

3 2

1

Air flow m³h

287

197

105

574

394

210

861 591

315

Sound pressure level dB(A)

37

25

20

29

27

21

40 28

22

Power level(W

46

32

18

92

64

36

138 96

54

Number of motors

1

2

3

Water temperature(c

room temperature(C)

Heating capacity(W)

Heating capacity(W

Heating capacity(W)

95/70

18

2870

2074

147

5633

4068

2898

8367 6026

4294

20

2782

2009

1433

5459

3942

2808

8108 5839

4161

80/60

18

2314

1671

1192

4541

3280

2336

6746 4858

3461

20

2226

1607

1146

4367

3153

2246

6486 4671

3328

75/60

18

2203

1591

1134

4324

3121

2224

6421 4624

3294

20

2113

1527

1088

4148

2995

2134

6161 4437

3161

70/55

18

1981

1430

1020

3886

2806

1999

5772 4157

2962

20

1891

1366

974

3712

2680

1910

5513 3970

2829

60/45

18

1535

1109

790

3012

2175

1550

4475 3222

2296

20

1446

1045

744

2838

2049

1460

4216 3036

2163

Water temperature(c

room temperature(C)

Heating capacity(W)

Heating capacity(W

Heating capacity(W)

6/12

26

Qk

1147

829

591

2252

1625

1158

3344

2408

1715

Qs

964

697

497

1892

1366

974

2810

2023

1442

24

Qk

896

647

462

1759

1269

905

2612

1881

1340

Qs

867

626

445

1701

1229

876

2527

1820

1297

8/14

26

Qk

867

626

446

1701

1229

876

2527

1820

1297

Qs

867

626

446

1701

1229

876

2527

1820

1297

24

Qk

698

504

359

1370

989

705

2034

1465

1044

Qs

698

504

359

1370

989

705

2034

1465

1044

10/15

26

Qk

712

515

367

1398

1010

719

2075

1495

1065

Qs

712

515

367

1398

1010

719

2075

1495

1065

24

Qk

611

441

315

1199

866

617

1780

1283

914

Qs

611

441

315

1199

866

617

1780

1283

914

12/16

26

Qk

626

452

322

1228

887

632

1823

1312

935

Qs

626

452

322

1228

887

632

1823

1312

935

24

Qk

527

381

272

1034

747

532

1535

1106

788

Qs

527

381

272

1034

747

532

1535

1106

788

16/18

26

Qk

461

333

238

905

653

466

1344

968

689

Qs

461

333

238

905

653

466

1344

968

689

24

Qk

375

271

193

736

531

379

1093

787

561

Qs

375

271

193

736

531

379

1093

787

561

The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity

 

Key Features of Heating & Cooling Floor Convectors

 

  • Dual-Functionality:These convectors are capable of both heating and cooling, making them ideal for year-round climate control. They efficiently switch between heating in the winter and cooling in the summer, ensuring a comfortable indoor temperature regardless of the season.
  • Space-Saving Installation:Installed within the floor, heating and cooling floor convectors save valuable space that would otherwise be taken up by wall or ceiling-mounted HVAC systems. Their recessed installation also enhances the room's aesthetics by keeping the units hidden from view.
  • Efficient Heat Exchange:These units are equipped with heat exchangers that can transfer heat or coolness efficiently. The heat exchanger typically consists of copper tubes and aluminum fins, which optimize the transfer of thermal energy, ensuring rapid temperature adjustment and minimal energy loss.
  • Adjustable Airflow:Many models feature adjustable fans that can be set to different speeds, allowing users to control the airflow and temperature distribution according to their specific comfort needs.
  • Quiet Operation:Designed for minimal noise, heating and cooling floor convectors are suitable for noise-sensitive environments such as bedrooms, offices, and libraries. Advanced models include noise reduction features to further ensure a quiet operation.
  • Enhanced Indoor Air Quality:Equipped with filters, these units can also improve indoor air quality by trapping dust, pollen, and other airborne particles. Some models may include advanced filtration systems or air purification options to provide cleaner, healthier air.
  • Energy Efficiency:Heating and cooling floor convectors are designed to be energy-efficient, utilizing advanced technologies to reduce energy consumption. This helps to lower utility costs while maintaining a comfortable indoor environment.
  • Customizable Design:Available in various sizes and finishes, these convectors can be customized to match the room's décor. The floor grilles can be tailored to fit seamlessly into the flooring, ensuring that the convector integrates well with the interior design.

 

Applications of Heating & Cooling Floor Convectors

 

  • Residential Homes:Ideal for living rooms, bedrooms, and hallways, these convectors provide discreet and efficient climate control, enhancing comfort in all seasons without taking up wall or ceiling space.
  • Commercial Buildings:Perfect for offices, conference rooms, and retail spaces where maintaining a consistent and comfortable temperature is critical for both employees and customers.
  • Public Buildings:Suitable for libraries, museums, and galleries, where quiet and efficient climate control is necessary to preserve the comfort of visitors and the condition of exhibits.
  • Healthcare Facilities:Used in hospitals, clinics, and nursing homes, providing reliable heating and cooling while ensuring minimal noise and maintaining high indoor air quality for patient well-being.
  • Educational Institutions:Applied in schools, universities, and training centers to create a comfortable learning environment that adapts to changing weather conditions throughout the year.
  • Hotels and Hospitality:Ideal for hotel rooms, lobbies, and common areas where guest comfort is paramount. The dual functionality of heating and cooling helps to maintain a pleasant atmosphere regardless of the season.
  • Industrial Applications:Used in warehouses, factories, and other industrial settings to provide a controlled climate, which can be essential for both worker comfort and the protection of sensitive equipment and products.

.jpg

.jpg

(1).jpg

 

 

product-907-456

 

FAQ

 

Q: How large is your factory?

A: Our factory covers an area of over 60,000 square meters.

Q: How many workers are there in your factory?

A: We have 165 workers.

Q: What machines do you have in your factory?

A: We have laser cutting machines, high-precision cutting machines, shearing machines, bending machines, high-speed punch presses, welding machines, and edge banding machines.

Q: Do you have a quality inspection department?

A: Yes, we have a quality inspection department with 6 quality inspectors.

Q: Who are your customers?

A: We have worked with well-known brands such as United Laboratories, Sun Yat-sen University, Nanyang Technological University of Singapore, China Central Television, and Beijing West Railway Station.

Q: Do you have an export license?

A: Yes, we have an export license.

Hot Tags: heating & cooling floor convector, China heating & cooling floor convector manufacturers, suppliers, factory, floor convector for workshop, floor convector iso certification, floor convector recyclable, floor convector heating area, floor convector csa certification, floor convector coil