Overview
Like the forced heat-only floor embedded convector, the Heating & Cooling Floor Convector provides filtered, heated and cooled air to the building in a "stealth" way through the convection heat exchange equipment concealed in the ground trench, which can provide heating and cooling, and is beautiful and space-saving. The heat exchange element used in the dual-purpose floor embedded convector is the surface cooler. This floor convector can be arranged in units or in a continuous manner.
Parameter
AHK340/150 Double pipe type
|
Model |
AHK340/150-1250 |
AHK340/150-2000 |
AHK340/150-2750 |
||||||||
|
Speed level |
3 |
2 |
1 |
3 |
2 |
1 |
3 |
2 |
1 |
||
|
Air flowm³h |
287 |
197 |
105 |
574 |
394 |
210 |
861 |
591 |
315 |
||
|
Sound pressure level dB(A) |
37 |
25 |
20 |
39 |
27 |
21 |
40 |
28 |
22 |
||
|
Power level(W |
46 |
32 |
18 |
92 |
64 |
36 |
138 |
96 |
54 |
||
|
Number of motors |
1 |
2 |
3 |
||||||||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
95/70 |
18 |
4949 |
3575 |
2548 |
9713 |
7014 |
4997 |
14427 |
10390 |
7403 |
|
|
20 |
4796 |
3464 |
2470 |
5412 |
6796 |
4842 |
13980 |
10067 |
7173 |
||
|
80/60 |
18 |
3990 |
2882 |
2055 |
7830 |
5654 |
4028 |
11630 |
8375 |
5967 |
|
|
20 |
3837 |
2771 |
1976 |
7529 |
5436 |
3874 |
11183 |
8053 |
5738 |
||
|
75/60 |
18 |
3798 |
2743 |
1956 |
7454 |
5382 |
3835 |
11070 |
7972 |
5680 |
|
|
20 |
3644 |
2633 |
1877 |
7152 |
5164 |
3679 |
10623 |
7650 |
5450 |
||
|
70/55 |
18 |
3415 |
2466 |
1758 |
6701 |
4838 |
3447 |
9951 |
7167 |
5107 |
|
|
20 |
3261 |
2355 |
1679 |
6399 |
4621 |
3292 |
9504 |
6845 |
4877 |
||
|
60/45 |
18 |
2647 |
1912 |
1363 |
5194 |
3750 |
2672 |
7715 |
5556 |
3958 |
|
|
20 |
2493 |
1801 |
1283 |
4892 |
3533 |
2517 |
7268 |
5234 |
3729 |
||
|
Water temperature(℃) |
room temperature(C) |
Heating capacity(w) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
6/12 |
26 |
Qk |
1434 |
1036 |
739 |
2814 |
2032 |
1448 |
4180 |
3010 |
2145 |
|
Qs |
1205 |
870 |
621 |
2364 |
1707 |
1217 |
3512 |
2529 |
1802 |
||
|
24 |
Qk |
1121 |
809 |
577 |
2198 |
1587 |
1131 |
3264 |
2351 |
1675 |
|
|
Qs |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
||
|
8/14 |
26 |
Qk |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
|
Qs |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
||
|
24 |
Qk |
873 |
630 |
449 |
'712 |
1237 |
881 |
2543 |
1832 |
1305 |
|
|
Qs |
873 |
630 |
449 |
712 |
1237 |
881 |
2543 |
1832 |
1305 |
||
|
10/15 |
26 |
Qk |
890 |
644 |
459 |
.747 |
1262 |
899 |
2595 |
1868 |
1331 |
|
Qs |
890 |
644 |
459 |
747 |
1262 |
899 |
2595 |
1868 |
1331 |
||
|
24 |
Qk |
764 |
552 |
393 |
-499 |
1082 |
771 |
2226 |
1603 |
1142 |
|
|
Qs |
764 |
552 |
393 |
1499 |
1082 |
771 |
2226 |
1603 |
1142 |
||
|
12/16 |
26 |
Qk |
782 |
565 |
403 |
535 |
1108 |
789 |
2279 |
1641 |
1169 |
|
Qs |
782 |
565 |
403 |
1535 |
1108 |
789 |
2279 |
1641 |
1169 |
||
|
24 |
Qk |
659 |
476 |
339 |
292 |
933 |
665 |
1919 |
1382 |
985 |
|
|
Qs |
749 |
476 |
339 |
292 |
933 |
665 |
1919 |
1382 |
985 |
||
|
16/18 |
26 |
Qk |
576 |
417 |
297 |
130 |
816 |
582 |
1679 |
1210 |
862 |
|
Qs |
576 |
417 |
297 |
1130 |
816 |
582 |
1679 |
1210 |
862 |
||
|
24 |
Qk |
469 |
338 |
241 |
920 |
664 |
473 |
366 |
984 |
701 |
|
|
Qs |
469 |
338 |
241 |
920 |
664 |
473 |
1366 |
984 |
701 |
||
|
The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity |
|||||||||||
AHK340/150 four pipe type
|
Model |
AHK340/150-1250 |
AHK340/150-2000 |
AHK340/150-2750 |
||||||||
|
Speed level |
3 |
2 |
1 |
3 |
2 |
1 |
3 2 |
1 |
|||
|
Air flow m³h |
287 |
197 |
105 |
574 |
394 |
210 |
861 591 |
315 |
|||
|
Sound pressure level dB(A) |
37 |
25 |
20 |
29 |
27 |
21 |
40 28 |
22 |
|||
|
Power level(W |
46 |
32 |
18 |
92 |
64 |
36 |
138 96 |
54 |
|||
|
Number of motors |
1 |
2 |
3 |
||||||||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
95/70 |
18 |
2870 |
2074 |
147 |
5633 |
4068 |
2898 |
8367 6026 |
4294 |
||
|
20 |
2782 |
2009 |
1433 |
5459 |
3942 |
2808 |
8108 5839 |
4161 |
|||
|
80/60 |
18 |
2314 |
1671 |
1192 |
4541 |
3280 |
2336 |
6746 4858 |
3461 |
||
|
20 |
2226 |
1607 |
1146 |
4367 |
3153 |
2246 |
6486 4671 |
3328 |
|||
|
75/60 |
18 |
2203 |
1591 |
1134 |
4324 |
3121 |
2224 |
6421 4624 |
3294 |
||
|
20 |
2113 |
1527 |
1088 |
4148 |
2995 |
2134 |
6161 4437 |
3161 |
|||
|
70/55 |
18 |
1981 |
1430 |
1020 |
3886 |
2806 |
1999 |
5772 4157 |
2962 |
||
|
20 |
1891 |
1366 |
974 |
3712 |
2680 |
1910 |
5513 3970 |
2829 |
|||
|
60/45 |
18 |
1535 |
1109 |
790 |
3012 |
2175 |
1550 |
4475 3222 |
2296 |
||
|
20 |
1446 |
1045 |
744 |
2838 |
2049 |
1460 |
4216 3036 |
2163 |
|||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
6/12 |
26 |
Qk |
1147 |
829 |
591 |
2252 |
1625 |
1158 |
3344 |
2408 |
1715 |
|
Qs |
964 |
697 |
497 |
1892 |
1366 |
974 |
2810 |
2023 |
1442 |
||
|
24 |
Qk |
896 |
647 |
462 |
1759 |
1269 |
905 |
2612 |
1881 |
1340 |
|
|
Qs |
867 |
626 |
445 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
||
|
8/14 |
26 |
Qk |
867 |
626 |
446 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
|
Qs |
867 |
626 |
446 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
||
|
24 |
Qk |
698 |
504 |
359 |
1370 |
989 |
705 |
2034 |
1465 |
1044 |
|
|
Qs |
698 |
504 |
359 |
1370 |
989 |
705 |
2034 |
1465 |
1044 |
||
|
10/15 |
26 |
Qk |
712 |
515 |
367 |
1398 |
1010 |
719 |
2075 |
1495 |
1065 |
|
Qs |
712 |
515 |
367 |
1398 |
1010 |
719 |
2075 |
1495 |
1065 |
||
|
24 |
Qk |
611 |
441 |
315 |
1199 |
866 |
617 |
1780 |
1283 |
914 |
|
|
Qs |
611 |
441 |
315 |
1199 |
866 |
617 |
1780 |
1283 |
914 |
||
|
12/16 |
26 |
Qk |
626 |
452 |
322 |
1228 |
887 |
632 |
1823 |
1312 |
935 |
|
Qs |
626 |
452 |
322 |
1228 |
887 |
632 |
1823 |
1312 |
935 |
||
|
24 |
Qk |
527 |
381 |
272 |
1034 |
747 |
532 |
1535 |
1106 |
788 |
|
|
Qs |
527 |
381 |
272 |
1034 |
747 |
532 |
1535 |
1106 |
788 |
||
|
16/18 |
26 |
Qk |
461 |
333 |
238 |
905 |
653 |
466 |
1344 |
968 |
689 |
|
Qs |
461 |
333 |
238 |
905 |
653 |
466 |
1344 |
968 |
689 |
||
|
24 |
Qk |
375 |
271 |
193 |
736 |
531 |
379 |
1093 |
787 |
561 |
|
|
Qs |
375 |
271 |
193 |
736 |
531 |
379 |
1093 |
787 |
561 |
||
|
The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity |
|||||||||||
Key Features of Heating & Cooling Floor Convectors
- Dual-Functionality:These convectors are capable of both heating and cooling, making them ideal for year-round climate control. They efficiently switch between heating in the winter and cooling in the summer, ensuring a comfortable indoor temperature regardless of the season.
- Space-Saving Installation:Installed within the floor, heating and cooling floor convectors save valuable space that would otherwise be taken up by wall or ceiling-mounted HVAC systems. Their recessed installation also enhances the room's aesthetics by keeping the units hidden from view.
- Efficient Heat Exchange:These units are equipped with heat exchangers that can transfer heat or coolness efficiently. The heat exchanger typically consists of copper tubes and aluminum fins, which optimize the transfer of thermal energy, ensuring rapid temperature adjustment and minimal energy loss.
- Adjustable Airflow:Many models feature adjustable fans that can be set to different speeds, allowing users to control the airflow and temperature distribution according to their specific comfort needs.
- Quiet Operation:Designed for minimal noise, heating and cooling floor convectors are suitable for noise-sensitive environments such as bedrooms, offices, and libraries. Advanced models include noise reduction features to further ensure a quiet operation.
- Enhanced Indoor Air Quality:Equipped with filters, these units can also improve indoor air quality by trapping dust, pollen, and other airborne particles. Some models may include advanced filtration systems or air purification options to provide cleaner, healthier air.
- Energy Efficiency:Heating and cooling floor convectors are designed to be energy-efficient, utilizing advanced technologies to reduce energy consumption. This helps to lower utility costs while maintaining a comfortable indoor environment.
- Customizable Design:Available in various sizes and finishes, these convectors can be customized to match the room's décor. The floor grilles can be tailored to fit seamlessly into the flooring, ensuring that the convector integrates well with the interior design.
Applications of Heating & Cooling Floor Convectors
- Residential Homes:Ideal for living rooms, bedrooms, and hallways, these convectors provide discreet and efficient climate control, enhancing comfort in all seasons without taking up wall or ceiling space.
- Commercial Buildings:Perfect for offices, conference rooms, and retail spaces where maintaining a consistent and comfortable temperature is critical for both employees and customers.
- Public Buildings:Suitable for libraries, museums, and galleries, where quiet and efficient climate control is necessary to preserve the comfort of visitors and the condition of exhibits.
- Healthcare Facilities:Used in hospitals, clinics, and nursing homes, providing reliable heating and cooling while ensuring minimal noise and maintaining high indoor air quality for patient well-being.
- Educational Institutions:Applied in schools, universities, and training centers to create a comfortable learning environment that adapts to changing weather conditions throughout the year.
- Hotels and Hospitality:Ideal for hotel rooms, lobbies, and common areas where guest comfort is paramount. The dual functionality of heating and cooling helps to maintain a pleasant atmosphere regardless of the season.
- Industrial Applications:Used in warehouses, factories, and other industrial settings to provide a controlled climate, which can be essential for both worker comfort and the protection of sensitive equipment and products.




FAQ
Q: How large is your factory?
Q: How many workers are there in your factory?
Q: What machines do you have in your factory?
Q: Do you have a quality inspection department?
Q: Who are your customers?
Q: Do you have an export license?
Hot Tags: heating & cooling floor convector, China heating & cooling floor convector manufacturers, suppliers, factory, floor convector for workshop, floor convector iso certification, floor convector recyclable, floor convector heating area, floor convector csa certification, floor convector coil