Overview
Surface Mounted Floor Convector is a type of heating unit installed on the surface of the floor rather than recessed into it. It operates using natural or forced convection to distribute heat efficiently throughout a space. These convectors are designed to provide effective heating while minimizing installation complexity and maximizing flexibility in placement. They are particularly suitable for areas where floor space is limited or where recessed installation is not feasible.
Parameter
AHK340/150 Double pipe type
|
Model |
AHK340/150-1250 |
AHK340/150-2000 |
AHK340/150-2750 |
||||||||
|
Speed level |
3 |
2 |
1 |
3 |
2 |
1 |
3 |
2 |
1 |
||
|
Air flowm³h |
287 |
197 |
105 |
574 |
394 |
210 |
861 |
591 |
315 |
||
|
Sound pressure level dB(A) |
37 |
25 |
20 |
39 |
27 |
21 |
40 |
28 |
22 |
||
|
Power level(W |
46 |
32 |
18 |
92 |
64 |
36 |
138 |
96 |
54 |
||
|
Number of motors |
1 |
2 |
3 |
||||||||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
95/70 |
18 |
4949 |
3575 |
2548 |
9713 |
7014 |
4997 |
14427 |
10390 |
7403 |
|
|
20 |
4796 |
3464 |
2470 |
5412 |
6796 |
4842 |
13980 |
10067 |
7173 |
||
|
80/60 |
18 |
3990 |
2882 |
2055 |
7830 |
5654 |
4028 |
11630 |
8375 |
5967 |
|
|
20 |
3837 |
2771 |
1976 |
7529 |
5436 |
3874 |
11183 |
8053 |
5738 |
||
|
75/60 |
18 |
3798 |
2743 |
1956 |
7454 |
5382 |
3835 |
11070 |
7972 |
5680 |
|
|
20 |
3644 |
2633 |
1877 |
7152 |
5164 |
3679 |
10623 |
7650 |
5450 |
||
|
70/55 |
18 |
3415 |
2466 |
1758 |
6701 |
4838 |
3447 |
9951 |
7167 |
5107 |
|
|
20 |
3261 |
2355 |
1679 |
6399 |
4621 |
3292 |
9504 |
6845 |
4877 |
||
|
60/45 |
18 |
2647 |
1912 |
1363 |
5194 |
3750 |
2672 |
7715 |
5556 |
3958 |
|
|
20 |
2493 |
1801 |
1283 |
4892 |
3533 |
2517 |
7268 |
5234 |
3729 |
||
|
Water temperature(℃) |
room temperature(C) |
Heating capacity(w) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
6/12 |
26 |
Qk |
1434 |
1036 |
739 |
2814 |
2032 |
1448 |
4180 |
3010 |
2145 |
|
Qs |
1205 |
870 |
621 |
2364 |
1707 |
1217 |
3512 |
2529 |
1802 |
||
|
24 |
Qk |
1121 |
809 |
577 |
2198 |
1587 |
1131 |
3264 |
2351 |
1675 |
|
|
Qs |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
||
|
8/14 |
26 |
Qk |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
|
Qs |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
||
|
24 |
Qk |
873 |
630 |
449 |
'712 |
1237 |
881 |
2543 |
1832 |
1305 |
|
|
Qs |
873 |
630 |
449 |
712 |
1237 |
881 |
2543 |
1832 |
1305 |
||
|
10/15 |
26 |
Qk |
890 |
644 |
459 |
.747 |
1262 |
899 |
2595 |
1868 |
1331 |
|
Qs |
890 |
644 |
459 |
747 |
1262 |
899 |
2595 |
1868 |
1331 |
||
|
24 |
Qk |
764 |
552 |
393 |
-499 |
1082 |
771 |
2226 |
1603 |
1142 |
|
|
Qs |
764 |
552 |
393 |
1499 |
1082 |
771 |
2226 |
1603 |
1142 |
||
|
12/16 |
26 |
Qk |
782 |
565 |
403 |
535 |
1108 |
789 |
2279 |
1641 |
1169 |
|
Qs |
782 |
565 |
403 |
1535 |
1108 |
789 |
2279 |
1641 |
1169 |
||
|
24 |
Qk |
659 |
476 |
339 |
292 |
933 |
665 |
1919 |
1382 |
985 |
|
|
Qs |
749 |
476 |
339 |
292 |
933 |
665 |
1919 |
1382 |
985 |
||
|
16/18 |
26 |
Qk |
576 |
417 |
297 |
130 |
816 |
582 |
1679 |
1210 |
862 |
|
Qs |
576 |
417 |
297 |
1130 |
816 |
582 |
1679 |
1210 |
862 |
||
|
24 |
Qk |
469 |
338 |
241 |
920 |
664 |
473 |
366 |
984 |
701 |
|
|
Qs |
469 |
338 |
241 |
920 |
664 |
473 |
1366 |
984 |
701 |
||
|
The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity |
|||||||||||
AHK340/150 four pipe type
|
Model |
AHK340/150-1250 |
AHK340/150-2000 |
AHK340/150-2750 |
||||||||
|
Speed level |
3 |
2 |
1 |
3 |
2 |
1 |
3 2 |
1 |
|||
|
Air flow m³h |
287 |
197 |
105 |
574 |
394 |
210 |
861 591 |
315 |
|||
|
Sound pressure level dB(A) |
37 |
25 |
20 |
29 |
27 |
21 |
40 28 |
22 |
|||
|
Power level(W |
46 |
32 |
18 |
92 |
64 |
36 |
138 96 |
54 |
|||
|
Number of motors |
1 |
2 |
3 |
||||||||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
95/70 |
18 |
2870 |
2074 |
147 |
5633 |
4068 |
2898 |
8367 6026 |
4294 |
||
|
20 |
2782 |
2009 |
1433 |
5459 |
3942 |
2808 |
8108 5839 |
4161 |
|||
|
80/60 |
18 |
2314 |
1671 |
1192 |
4541 |
3280 |
2336 |
6746 4858 |
3461 |
||
|
20 |
2226 |
1607 |
1146 |
4367 |
3153 |
2246 |
6486 4671 |
3328 |
|||
|
75/60 |
18 |
2203 |
1591 |
1134 |
4324 |
3121 |
2224 |
6421 4624 |
3294 |
||
|
20 |
2113 |
1527 |
1088 |
4148 |
2995 |
2134 |
6161 4437 |
3161 |
|||
|
70/55 |
18 |
1981 |
1430 |
1020 |
3886 |
2806 |
1999 |
5772 4157 |
2962 |
||
|
20 |
1891 |
1366 |
974 |
3712 |
2680 |
1910 |
5513 3970 |
2829 |
|||
|
60/45 |
18 |
1535 |
1109 |
790 |
3012 |
2175 |
1550 |
4475 3222 |
2296 |
||
|
20 |
1446 |
1045 |
744 |
2838 |
2049 |
1460 |
4216 3036 |
2163 |
|||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
6/12 |
26 |
Qk |
1147 |
829 |
591 |
2252 |
1625 |
1158 |
3344 |
2408 |
1715 |
|
Qs |
964 |
697 |
497 |
1892 |
1366 |
974 |
2810 |
2023 |
1442 |
||
|
24 |
Qk |
896 |
647 |
462 |
1759 |
1269 |
905 |
2612 |
1881 |
1340 |
|
|
Qs |
867 |
626 |
445 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
||
|
8/14 |
26 |
Qk |
867 |
626 |
446 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
|
Qs |
867 |
626 |
446 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
||
|
24 |
Qk |
698 |
504 |
359 |
1370 |
989 |
705 |
2034 |
1465 |
1044 |
|
|
Qs |
698 |
504 |
359 |
1370 |
989 |
705 |
2034 |
1465 |
1044 |
||
|
10/15 |
26 |
Qk |
712 |
515 |
367 |
1398 |
1010 |
719 |
2075 |
1495 |
1065 |
|
Qs |
712 |
515 |
367 |
1398 |
1010 |
719 |
2075 |
1495 |
1065 |
||
|
24 |
Qk |
611 |
441 |
315 |
1199 |
866 |
617 |
1780 |
1283 |
914 |
|
|
Qs |
611 |
441 |
315 |
1199 |
866 |
617 |
1780 |
1283 |
914 |
||
|
12/16 |
26 |
Qk |
626 |
452 |
322 |
1228 |
887 |
632 |
1823 |
1312 |
935 |
|
Qs |
626 |
452 |
322 |
1228 |
887 |
632 |
1823 |
1312 |
935 |
||
|
24 |
Qk |
527 |
381 |
272 |
1034 |
747 |
532 |
1535 |
1106 |
788 |
|
|
Qs |
527 |
381 |
272 |
1034 |
747 |
532 |
1535 |
1106 |
788 |
||
|
16/18 |
26 |
Qk |
461 |
333 |
238 |
905 |
653 |
466 |
1344 |
968 |
689 |
|
Qs |
461 |
333 |
238 |
905 |
653 |
466 |
1344 |
968 |
689 |
||
|
24 |
Qk |
375 |
271 |
193 |
736 |
531 |
379 |
1093 |
787 |
561 |
|
|
Qs |
375 |
271 |
193 |
736 |
531 |
379 |
1093 |
787 |
561 |
||
|
The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity |
|||||||||||


Key Features of Surface Mounted Floor Convectors
- Easy Installation:Surface mounted floor convectors are designed for straightforward installation on top of the floor surface, requiring minimal modifications to existing structures. This makes them ideal for retrofitting heating systems into buildings without the need for extensive renovation.
- Flexible Placement:These convectors can be installed virtually anywhere on the floor surface, providing flexibility in placement to suit the layout and design of the room. They are often used in areas where wall space is limited or where recessed installation is not practical.
- Efficient Heat Distribution:Surface mounted floor convectors utilize natural convection or forced convection to distribute heat evenly throughout the space. This ensures consistent heating and helps maintain a comfortable indoor temperature.
- Compact Design:Despite being mounted on the floor surface, these convectors typically have a slim and compact design that minimizes obstruction and maximizes usable floor space. This makes them suitable for installation in areas with limited space.
- Durable Construction:Constructed from high-quality materials such as steel or aluminum, surface mounted floor convectors are built to withstand regular use and provide long-lasting performance.
- Customizable Grilles:The top grilles of surface mounted floor convectors can be customized to match the flooring and room decor. Available in various materials, finishes, and colors, these grilles can be tailored to blend seamlessly with the surrounding environment.
- Energy Efficiency:Designed for optimal heat output with minimal energy consumption, surface mounted floor convectors often feature advanced heat exchangers and insulation to maximize efficiency and reduce energy costs.
- Low Noise Operation:Many surface mounted floor convectors are designed to operate quietly, making them suitable for noise-sensitive environments such as bedrooms, offices, and libraries.
Applications of Surface Mounted Floor Convectors
- Residential Spaces:Ideal for homes, particularly in rooms with limited wall space or where recessed installation is not possible, such as kitchens, bathrooms, and utility rooms.
- Commercial Environments:Suitable for offices, retail spaces, and reception areas where a discreet and efficient heating solution is required that does not interfere with the layout or aesthetics of the space.
- Public Buildings:Used in libraries, community centers, and recreational facilities where effective heating is needed without detracting from the design or function of the space.
- Healthcare Facilities:Applied in hospitals, clinics, and care homes to provide reliable heating that does not interfere with the environment and ensures the comfort of patients and staff.
- Educational Institutions:Employed in schools, universities, and training centers to create a comfortable learning environment, especially in areas with limited wall space or complex layouts.
- Hospitality Industry:Suitable for hotel rooms, lobbies, and common areas where maintaining guest comfort is essential while ensuring the heating system remains unobtrusive.
- Industrial Settings:Used in warehouses, factories, and workshops where surface mounted floor convectors provide efficient heating without taking up valuable floor or wall space.




FAQ
Q: How do you resolve issues if there are malfunctions during the use of the equipment?
Q: Do you provide after-sales service?
Q: How is your product packaging?
Q: Can you arrange shipment for customers?
Q: Where are your products used?
Q: What machines do you have in your factory?
Hot Tags: surface mounted floor convector, China surface mounted floor convector manufacturers, suppliers, factory, Residential Floor Convector, Exposed Vertical Fan Coil Unit, combined air handling unit, heat recovery ventilator, Forced Floor Convector, Surface Mounted Floor Convector