Hydronic Floor Convector is a type of heating unit that utilizes hot water or steam to provide efficient and consistent heating for indoor spaces. These convectors are typically installed either recessed into the floor or mounted on the surface, depending on the specific requirements of the application. Hydronic floor convectors offer a reliable and energy-efficient solution for heating rooms, particularly in areas where traditional heating systems may not be practical or cost-effective.
Parameter
AHK340/150 Double pipe type
|
Model |
AHK340/150-1250 |
AHK340/150-2000 |
AHK340/150-2750 |
||||||||
|
Speed level |
3 |
2 |
1 |
3 |
2 |
1 |
3 |
2 |
1 |
||
|
Air flowm³h |
287 |
197 |
105 |
574 |
394 |
210 |
861 |
591 |
315 |
||
|
Sound pressure level dB(A) |
37 |
25 |
20 |
39 |
27 |
21 |
40 |
28 |
22 |
||
|
Power level(W |
46 |
32 |
18 |
92 |
64 |
36 |
138 |
96 |
54 |
||
|
Number of motors |
1 |
2 |
3 |
||||||||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
95/70 |
18 |
4949 |
3575 |
2548 |
9713 |
7014 |
4997 |
14427 |
10390 |
7403 |
|
|
20 |
4796 |
3464 |
2470 |
5412 |
6796 |
4842 |
13980 |
10067 |
7173 |
||
|
80/60 |
18 |
3990 |
2882 |
2055 |
7830 |
5654 |
4028 |
11630 |
8375 |
5967 |
|
|
20 |
3837 |
2771 |
1976 |
7529 |
5436 |
3874 |
11183 |
8053 |
5738 |
||
|
75/60 |
18 |
3798 |
2743 |
1956 |
7454 |
5382 |
3835 |
11070 |
7972 |
5680 |
|
|
20 |
3644 |
2633 |
1877 |
7152 |
5164 |
3679 |
10623 |
7650 |
5450 |
||
|
70/55 |
18 |
3415 |
2466 |
1758 |
6701 |
4838 |
3447 |
9951 |
7167 |
5107 |
|
|
20 |
3261 |
2355 |
1679 |
6399 |
4621 |
3292 |
9504 |
6845 |
4877 |
||
|
60/45 |
18 |
2647 |
1912 |
1363 |
5194 |
3750 |
2672 |
7715 |
5556 |
3958 |
|
|
20 |
2493 |
1801 |
1283 |
4892 |
3533 |
2517 |
7268 |
5234 |
3729 |
||
|
Water temperature(℃) |
room temperature(C) |
Heating capacity(w) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
6/12 |
26 |
Qk |
1434 |
1036 |
739 |
2814 |
2032 |
1448 |
4180 |
3010 |
2145 |
|
Qs |
1205 |
870 |
621 |
2364 |
1707 |
1217 |
3512 |
2529 |
1802 |
||
|
24 |
Qk |
1121 |
809 |
577 |
2198 |
1587 |
1131 |
3264 |
2351 |
1675 |
|
|
Qs |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
||
|
8/14 |
26 |
Qk |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
|
Qs |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
||
|
24 |
Qk |
873 |
630 |
449 |
'712 |
1237 |
881 |
2543 |
1832 |
1305 |
|
|
Qs |
873 |
630 |
449 |
712 |
1237 |
881 |
2543 |
1832 |
1305 |
||
|
10/15 |
26 |
Qk |
890 |
644 |
459 |
.747 |
1262 |
899 |
2595 |
1868 |
1331 |
|
Qs |
890 |
644 |
459 |
747 |
1262 |
899 |
2595 |
1868 |
1331 |
||
|
24 |
Qk |
764 |
552 |
393 |
-499 |
1082 |
771 |
2226 |
1603 |
1142 |
|
|
Qs |
764 |
552 |
393 |
1499 |
1082 |
771 |
2226 |
1603 |
1142 |
||
|
12/16 |
26 |
Qk |
782 |
565 |
403 |
535 |
1108 |
789 |
2279 |
1641 |
1169 |
|
Qs |
782 |
565 |
403 |
1535 |
1108 |
789 |
2279 |
1641 |
1169 |
||
|
24 |
Qk |
659 |
476 |
339 |
292 |
933 |
665 |
1919 |
1382 |
985 |
|
|
Qs |
749 |
476 |
339 |
292 |
933 |
665 |
1919 |
1382 |
985 |
||
|
16/18 |
26 |
Qk |
576 |
417 |
297 |
130 |
816 |
582 |
1679 |
1210 |
862 |
|
Qs |
576 |
417 |
297 |
1130 |
816 |
582 |
1679 |
1210 |
862 |
||
|
24 |
Qk |
469 |
338 |
241 |
920 |
664 |
473 |
366 |
984 |
701 |
|
|
Qs |
469 |
338 |
241 |
920 |
664 |
473 |
1366 |
984 |
701 |
||
|
The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity |
|||||||||||
AHK340/150 four pipe type
|
Model |
AHK340/150-1250 |
AHK340/150-2000 |
AHK340/150-2750 |
||||||||
|
Speed level |
3 |
2 |
1 |
3 |
2 |
1 |
3 2 |
1 |
|||
|
Air flow m³h |
287 |
197 |
105 |
574 |
394 |
210 |
861 591 |
315 |
|||
|
Sound pressure level dB(A) |
37 |
25 |
20 |
29 |
27 |
21 |
40 28 |
22 |
|||
|
Power level(W |
46 |
32 |
18 |
92 |
64 |
36 |
138 96 |
54 |
|||
|
Number of motors |
1 |
2 |
3 |
||||||||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
95/70 |
18 |
2870 |
2074 |
147 |
5633 |
4068 |
2898 |
8367 6026 |
4294 |
||
|
20 |
2782 |
2009 |
1433 |
5459 |
3942 |
2808 |
8108 5839 |
4161 |
|||
|
80/60 |
18 |
2314 |
1671 |
1192 |
4541 |
3280 |
2336 |
6746 4858 |
3461 |
||
|
20 |
2226 |
1607 |
1146 |
4367 |
3153 |
2246 |
6486 4671 |
3328 |
|||
|
75/60 |
18 |
2203 |
1591 |
1134 |
4324 |
3121 |
2224 |
6421 4624 |
3294 |
||
|
20 |
2113 |
1527 |
1088 |
4148 |
2995 |
2134 |
6161 4437 |
3161 |
|||
|
70/55 |
18 |
1981 |
1430 |
1020 |
3886 |
2806 |
1999 |
5772 4157 |
2962 |
||
|
20 |
1891 |
1366 |
974 |
3712 |
2680 |
1910 |
5513 3970 |
2829 |
|||
|
60/45 |
18 |
1535 |
1109 |
790 |
3012 |
2175 |
1550 |
4475 3222 |
2296 |
||
|
20 |
1446 |
1045 |
744 |
2838 |
2049 |
1460 |
4216 3036 |
2163 |
|||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
6/12 |
26 |
Qk |
1147 |
829 |
591 |
2252 |
1625 |
1158 |
3344 |
2408 |
1715 |
|
Qs |
964 |
697 |
497 |
1892 |
1366 |
974 |
2810 |
2023 |
1442 |
||
|
24 |
Qk |
896 |
647 |
462 |
1759 |
1269 |
905 |
2612 |
1881 |
1340 |
|
|
Qs |
867 |
626 |
445 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
||
|
8/14 |
26 |
Qk |
867 |
626 |
446 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
|
Qs |
867 |
626 |
446 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
||
|
24 |
Qk |
698 |
504 |
359 |
1370 |
989 |
705 |
2034 |
1465 |
1044 |
|
|
Qs |
698 |
504 |
359 |
1370 |
989 |
705 |
2034 |
1465 |
1044 |
||
|
10/15 |
26 |
Qk |
712 |
515 |
367 |
1398 |
1010 |
719 |
2075 |
1495 |
1065 |
|
Qs |
712 |
515 |
367 |
1398 |
1010 |
719 |
2075 |
1495 |
1065 |
||
|
24 |
Qk |
611 |
441 |
315 |
1199 |
866 |
617 |
1780 |
1283 |
914 |
|
|
Qs |
611 |
441 |
315 |
1199 |
866 |
617 |
1780 |
1283 |
914 |
||
|
12/16 |
26 |
Qk |
626 |
452 |
322 |
1228 |
887 |
632 |
1823 |
1312 |
935 |
|
Qs |
626 |
452 |
322 |
1228 |
887 |
632 |
1823 |
1312 |
935 |
||
|
24 |
Qk |
527 |
381 |
272 |
1034 |
747 |
532 |
1535 |
1106 |
788 |
|
|
Qs |
527 |
381 |
272 |
1034 |
747 |
532 |
1535 |
1106 |
788 |
||
|
16/18 |
26 |
Qk |
461 |
333 |
238 |
905 |
653 |
466 |
1344 |
968 |
689 |
|
Qs |
461 |
333 |
238 |
905 |
653 |
466 |
1344 |
968 |
689 |
||
|
24 |
Qk |
375 |
271 |
193 |
736 |
531 |
379 |
1093 |
787 |
561 |
|
|
Qs |
375 |
271 |
193 |
736 |
531 |
379 |
1093 |
787 |
561 |
||
|
The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity |
|||||||||||


Key Features of Hydronic Floor Convectors
- Hot Water or Steam Heating:Hydronic floor convectors operate by circulating hot water or steam through a network of pipes within the unit. This heating medium transfers thermal energy to the surrounding air, effectively warming the room.
- Precise Temperature Control:These convectors often come equipped with thermostatic controls or electronic temperature sensors, allowing for precise temperature regulation and ensuring optimal comfort levels.
- Quiet Operation:Hydronic floor convectors operate quietly, making them suitable for noise-sensitive environments such as bedrooms, offices, and libraries.
- Energy Efficiency:By using water or steam as the heating medium, hydronic floor convectors offer excellent energy efficiency and can be integrated with renewable energy sources such as solar thermal systems.
- Versatile Installation:Hydronic floor convectors can be installed in various locations, including underfloor or surface-mounted installations, depending on the specific requirements of the space.
- Compact Design:These convectors typically have a slim and compact design, minimizing their footprint and maximizing usable floor space.
- Safety Features:Many hydronic floor convectors are equipped with safety features such as temperature sensors and pressure relief valves, ensuring safe operation and preventing overheating or leaks.
- Quick Heat-Up Time:Hydronic floor convectors heat up quickly, providing almost instant warmth to the room when hot water or steam is circulated through the unit.
Applications of Hydronic Floor Convectors
- Residential Spaces:Ideal for heating bedrooms, living rooms, bathrooms, and other areas within residential homes, providing efficient and comfortable warmth.
- Commercial Buildings:Suitable for offices, retail stores, restaurants, and other commercial spaces where efficient and discreet heating is required.
- Public Buildings:Used in libraries, community centers, schools, and other public facilities to provide consistent heating throughout the space.
- Healthcare Facilities:Applied in hospitals, clinics, and nursing homes to ensure a comfortable and warm environment for patients and staff.
- Hospitality Industry:Suitable for hotel rooms, lobbies, and common areas, providing guests with comfortable warmth during their stay.
- Industrial Settings:Used in warehouses, factories, and workshops to provide localized heating in specific areas or zones.




FAQ
Q: What is your delivery time?
Q: What are your payment terms?
Q: What payment methods do you accept?
essaging methods to avoid any delays.
Q: What are your delivery terms?
Q: Question:What are your payment methods?
2,Design Manufacturing) and OEM (Original Equipment Manufacturing) orders: We require a 30% deposit and the remaining 70% as the balance payment.
Q: Where is your factory located?
Hot Tags: hydronic floor convector, China hydronic floor convector manufacturers, suppliers, factory, powder coated floor convector, floor convector with timer, floor convector thermometer, floor convector for hotel, replacement floor convector, silver floor convector