The Industrial Air Handling Unit is a critical equipment in industrial environments, used for air handling and maintaining indoor environmental comfort and suitability. These units are typically employed in large industrial facilities such as factories, workshops, and warehouses, with designs and functionalities tailored to meet the specific requirements and challenges of industrial settings.
Send Inquiry

Overview

 

The outdoor Air Handling Unit is a critical equipment in industrial environments, used for air handling and maintaining indoor environmental comfort and suitability. These units are typically employed in large industrial facilities such as factories, workshops, and warehouses, with designs and functionalities tailored to meet the specific requirements and challenges of industrial settings.

 

Parameter

 

Cooling, water volume, water resistance

 

Cooling conditions: Inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃, inlet water temperature 7℃, outlet water temperature 12℃

Model

Two-row pipe

Four-row pipe

six-row pipe

eight-row pipe

cooling(KW

Water volume(m³/h)

Water resistance (KPa)

cooling(KW)

Water volume (m h)

Water resistance (KPa)

cooling(kW)

Water volume

(m³/h)

Water resistance (KPa)

cooling

(KW

Water volume

(m³/h)

Water resistance (KPa)

ZK-05

18.8

3.23

10.1

29.4

5.01

9.76

37.8

6.49

16.99

45.7

7.85

10.44

ZK-10

34.7

5.89

10.5

58.6

10.35

11.65

75.4

12.96

10.08

91.2

15.70

12.82

ZK-15

53.4

9.16

9.8

87.9

15.08

7.21

113.1

19.5

12.11

136.8

23.52

15.12

ZK-20

70.6

12.14

9.8

117.3

20.16

8.25

150.8

26.21

14.07

182.4

31.96

17.48

ZK-25

92.9

15.83

11.6

146.1

25.12

10.24

188.1

33.90

11.77

227.5

39.11

14.76

ZK-30

113.6

19.2

11.8

175.2

30.12

11.16

225.6

38.90

13.10

273.4

47.00

16.28

ZK-40

144.4

24.82

12.4

232.8

40.03

12.93

300.2

51.61

15.73

362.2

62.27

19.20

ZK-50

180.5

30.61

10.4

292.3

50.25

7.47

375.3

64.52

17.00

435.80

74.93

15.70

ZK-60

216.6

37.24

9.4

349.2

60.04

7.47

450.3

77.42

17.00

544.80

93.67

15.70

ZK-80

287.2

49.1

9.1

464.6

79.88

8.5

598.4

102.89

19.5

724.8

124.62

17.9

ZK-100

357.0

61.38

9.5

578.2

99.41

8.5

746.5

128.35

19.5

904.2

155.46

17.9

ZK-120

428.4

73.65

9.5

693.6

118.91

8.5

895.2

153.91

19.5

1084.8

186.51

17.9

ZK-160

591.2

101.65

11.2

921.6

158.48

10.3

1190.4

204.67

20.1

1443.2

255.93

32.4

ZK-200

740.1

127.25

12.8

1152.2

199.3

13.1

1488.1

255.86

26.4

1804.3

310.22

42.4

 

Note: The performance parameters of the unit at a headwind speed of 2.5m/s

 

 

Key Features of outdoor AHUs

 

 

Weather-Resistant Construction
Durable casing (usually galvanized steel or aluminum alloy) with anti-corrosion coating, rainproof structure, and sun-shielding insulation.

Integrated or Modular Design
Can be delivered as a single compact unit or modular sections for easier on-site assembly.

Thermal & Acoustic Insulation
Panels with high-density insulation to ensure thermal performance and noise reduction.

Flexible Access Panels
Service doors with external locks and weather gaskets for maintenance under any condition.

Drainage and Condensate Management
Sloped drain pans and external drainage points to prevent water accumulation.

 

Advantages of outdoor AHUs

 

No Indoor Space Required
Maximizes usable indoor area-ideal for high-density commercial buildings.

Direct Outdoor Air Intake
Simplifies duct routing for fresh air supply and exhaust air discharge.

Pre-Assembled Units Available
Shortens installation time and reduces on-site labor.

Energy Recovery Options
Can include enthalpy wheels or plate heat exchangers to reclaim exhaust air energy.

Robust for Harsh Climates
Proven performance in coastal, desert, and cold regions.

Blower:Blower bearings use lubricated precision ball bearings, and the outer seal ring of the bearing is made of polyamide rubber, which is resistant to high temperatures and can absorb vibration and mechanism noise. The impeller of the purification series air conditioner fan is made of high-quality steel plate (backward-inclined impeller is configured as required), which is more in line with the specific shape of aerodynamics, with high efficiency and low noise.

 

22

Surface cooler: The copper tube and aluminum sheet structure is adopted. The copper tube and aluminum sheet are tightly combimechanical or water pressure expansion, and tested by 1.6Mpa air pressure to ensure the minimum contact thermal resistance to achieve the best heat transfer effect. The condensate tray is made of high-quality steel plate or SUS304, double-layer filled with polyurethane foam, and the slope design is more conducive to the discharge of condensate, which has obtained the national patent

product-630-473
Filter: Primary, medium and high efficiency filtration sections are equipped with differential pressure gauges to monitor the initial and final resistance of the filter, providing a scientific basis for filter replacement. Primary, medium and high efficiency filters, as well as photohydrogen ion, high voltage electrostatic and electronic purification filters can be configured according to requirements.
product-630-473

.jpg

(1).jpg

 

3

 

 

FAQ

 

Q: Where is your factory located?

A: Our factory is located in Taixing City, Taizhou, Jiangsu Province, China.

Q: When was your factory established?

A: Our factory was established in 2010.

Q: What are your main markets?

A: Our main markets include Europe, North America, South America, Australia, and Southeast Asia.

Q: How large is your factory?

A: Our factory covers an area of over 60,000 square meters.

Q: How many workers are there in your factory?

A: We have 165 workers.

Hot Tags: ahu outdoor unit, China ahu outdoor unit manufacturers, suppliers, factory, luxury items, latest products, popular items, long lasting products, cool items, useful commodities