Modular Air Handler
Modular Air Handler

Modular Air Handler

A Modular Air Handling Unit (AHU) is a versatile HVAC system designed to provide heating, ventilation, and air conditioning (HVAC) functions in a modular and flexible manner. Unlike traditional AHUs, which are typically large and centralized, modular AHUs consist of individual modules or sections that can be assembled and configured to meet specific project requirements.
Send Inquiry
Overview

 

modular air handler is a versatile component in heating, ventilation, and air conditioning (HVAC) systems, designed to provide flexibility in installation and operation. Unlike traditional air handlers, modular units consist of multiple sections or modules that can be combined in various configurations to meet specific space constraints and performance requirements.

 

Parameter

 

Cooling, water volume, water resistance

 

Cooling conditions: Inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃, inlet water temperature 7℃, outlet water temperature 12℃

Model

Two-row pipe

Four-row pipe

six-row pipe

eight-row pipe

cooling(KW

Water volume(m³/h)

Water resistance (KPa)

cooling(KW)

Water volume (m h)

Water resistance (KPa)

cooling(kW)

Water volume

(m³/h)

Water resistance (KPa)

cooling

(KW

Water volume

(m³/h)

Water resistance (KPa)

ZK-05

18.8

3.23

10.1

29.4

5.01

9.76

37.8

6.49

16.99

45.7

7.85

10.44

ZK-10

34.7

5.89

10.5

58.6

10.35

11.65

75.4

12.96

10.08

91.2

15.70

12.82

ZK-15

53.4

9.16

9.8

87.9

15.08

7.21

113.1

19.5

12.11

136.8

23.52

15.12

ZK-20

70.6

12.14

9.8

117.3

20.16

8.25

150.8

26.21

14.07

182.4

31.96

17.48

ZK-25

92.9

15.83

11.6

146.1

25.12

10.24

188.1

33.90

11.77

227.5

39.11

14.76

ZK-30

113.6

19.2

11.8

175.2

30.12

11.16

225.6

38.90

13.10

273.4

47.00

16.28

ZK-40

144.4

24.82

12.4

232.8

40.03

12.93

300.2

51.61

15.73

362.2

62.27

19.20

ZK-50

180.5

30.61

10.4

292.3

50.25

7.47

375.3

64.52

17.00

435.80

74.93

15.70

ZK-60

216.6

37.24

9.4

349.2

60.04

7.47

450.3

77.42

17.00

544.80

93.67

15.70

ZK-80

287.2

49.1

9.1

464.6

79.88

8.5

598.4

102.89

19.5

724.8

124.62

17.9

ZK-100

357.0

61.38

9.5

578.2

99.41

8.5

746.5

128.35

19.5

904.2

155.46

17.9

ZK-120

428.4

73.65

9.5

693.6

118.91

8.5

895.2

153.91

19.5

1084.8

186.51

17.9

ZK-160

591.2

101.65

11.2

921.6

158.48

10.3

1190.4

204.67

20.1

1443.2

255.93

32.4

ZK-200

740.1

127.25

12.8

1152.2

199.3

13.1

1488.1

255.86

26.4

1804.3

310.22

42.4

 

Note: The performance parameters of the unit at a headwind speed of 2.5m/s

 

Cooling condition correction factor

Correction Factor K1 for Cooling Capacity and Water Flow under Different Inlet Air and Water Temperatures

air temperature

Water temperature℃

Wet bulb

Temperature

Dry bulb

Temperature

5/10

6/11

7/12

8/13

9/14

17

19-27

0.83

0.76

0.67

0.62

0.57

18

20-30

0.94

1.85

0.76

0.68

0.58

19

21-31

1.07

0.97

0.88

0.79

0.71

19.5

21-33

1.15

1.06

1.00

0.86

0.78

20

22-33

1.20

1.10

1.03

0.90

0.81

21

23-36

1.34

1.24

1.14

1.03

0.93

22

24-39

1.48

1.38

1.28

1.18

1.07

23

25-42

1.63

1.53

1.43

1.32

1.22

24

26-45

1.79

1.69

1.59

1.47

1.36

25

27-48

   

1.75

1.64

1.53

26

28-48

   

1.92

1.81

1.70

27

29-48

   

2.09

1.98

1.87

28

30-50

   

2.26

2.16

2.05

29

31-52

   

2.40

2.32

2.2

 

Correction Factor K3 for Cooling Capacity and Water Flow under Different Inlet Air and Water Temperatures

 

Headwind speed

2.0

2.3

2.5

2.7

3.0

3.3

3.5

coefficient

0.81

0.92

1.0

1.07

1.17

1.26

1.32

Correction Factor K2 for Water Resistance under Different Inlet Air and Water Temperatures

air temperature

Water temperature℃

Wet bulb

Temperature

Dry bulb

Temperature

5/10

6/11

7/12

8/13

9/14

18

20-30

0.90

0.74

0.60

0.49

0.36

19

21-31

1.13

0.95

0.77

0.65

0.54

19.5

21-33

1.35

1.15

1.00

0.78

0.63

20

22-33

1.41

1.20

1.05

0.82

0.67

21

23-36

1.72

1.49

1.27

1.06

0.86

22

24-39

2.08

1.82

1.57

1.34

1.12

23

25-42

2.48

2.20

1.93

1.66

1.14

24

26-45

2.95

2.62

2.33

2.03

1.76

25

27-48

   

2.78

2.46

2.16

26

28-48

   

3.30

2.94

2.60

27

29-48

   

3.80

3.50

3.12

28

30-50

   

4.14

4.10

3.70

29

31-52

   

4.14

4.10

3.70

 

 

Correction Factor K4 for Water Resistance under Different Inlet Air and Water Temperatures

 

Headwind speed

2.0

2.3

2.5

2.7

3.0

3.3

3.5

coefficient

0.9

0.96

1.0

1.04

1.1

1.16

1.2

Ps:1.The above correction factors are determined based on the average values of various units. For small units (05~15), multiply by 0.95; for large units (50-200), multiply by 1.08.
2.The above correction factors are approximate values and are for reference only.

 

Correction under different wind speeds, inlet air temperature, and water temperature conditions:

Actual cooling capacity = Cooling capacity from Table 1 × K1 × K3
Actual water flow = Water flow from Table 1 × K1 × K3
Actual water resistance = Water resistance from Table 1 × K2 × K4

 

Example: Selecting YG-20 air conditioner, the cooling coil face wind speed is 2.5 m/s. According to Table 1, the cooling capacity is 150.8 kW, water flow is 26.21 m³/h, and water resistance is 14.07 kPa. Determine the actual cooling capacity, water flow, and water resistance when the inlet air dry-bulb temperature is 27°C, wet-bulb temperature is 21°C, inlet water temperature is 7°C, and outlet water temperature is 12°C.

 

Solution: From Table K1, the correction factor K1 = 1.14. From Table K2, the correction factor K2 = 1.27.
Therefore:

Actual cooling capacity (Q) = Standard condition cooling capacity × K1 = 150.8 × 1.14 = 171.91 kW
Actual water flow (V) = Standard condition water flow × K1 = 26.21 × 1.14 = 29.88 m³/h
Actual water resistance (P) = Standard condition water resistance × K2 = 14.07 × 1.27 = 17.87 kPa

 

Heating, water volume, water resistance

Heating conditions: air inlet temperature 15℃, water inlet temperature 60℃

Model

Two-row pipe

four-row pipe

six-row pipe

eight-row pipe

Heating(KW)

Water volume (m/h)

Water resistance (KPa)

Heating

(KW

Water volume

(mh)

Water resistance (KPa)

Heating

(KW)

Water volume

(m³h)

Water resistance

(KPa)

Heating(KW)

Water volume m/h)

Water resistance

(KPa)

ZK-05

34.1

3.23

10.1

50.6

5.01

9.76

59.2

6.49

16.99

77.1

7.85

10.44

ZK-10

67.1

5.89

10.5

99.8

10.35

11.65

124.8

12.96

10.08

151.0

15.70

12.82

ZK-15

101.8

9.16

9.8

149.7

15.08

7.21

173.5

19.5

12.11

205.1

23.52

15.12

ZK-20

135.6

12.14

9.8

199.0

20.16

8.25

248.8

26.21

14.07

289.3

31.96

17.48

ZK-25

168.7

15.83

11.6

249.5

25.12

10.24

311.2

33.90

11.77

353.3

39.11

14.76

ZK-30

202.6

19.2

11.8

304.5

30.12

11.16

380.9

38.90

13.10

448.3

47.00

16.28

ZK-40

270.4

24.82

12.4

399.2

40.03

12.93

480.8

51.61

15.73

592.4

62.27

19.20

ZK-50

337.3

30.61

10.4

512.3

50.25

7.47

556.8

64.52

17.00

641.8

74.93

15.70

ZK-60

404.7

37.24

9.4

609.4

60.04

7.47

581.2

77.42

17.00

766.8

93.67

15.70

ZK-80

539.5

49.1

9.1

796.0

79.88

8.5

386.2

102.89

19.5

1006.0

124.62

17.9

ZK-100

674.5

61.38

9.5

985.1

99.41

8.5

1127.6

128.35

19.5

1272.3

155.46

17.9

ZK-120

808.9

73.65

9.5

1185.9

118.91

8.5

1362.5

153.91

19.5

1533.6

186.51

17.9

ZK-160

1077.8

101.65

11.2

1576.0

158.48

10.3

1688.4

204.67

20.1

2083.2

255.93

32.4

ZK-200

1346.2

127.25

12.8

1970.8

199.3

13.1

2032.7

255.86

26.4

2606.2

310.22

42.4

 

Note: 1. The unit's performance reference at a headwind speed of 2.5m/s
2. The coil is a dual-purpose coil for hot and cold applications

 

Key Features of Modular Air Handlers

 

●Flexible Configuration:

Modular air handlers can be assembled in different combinations, allowing customization to fit unique building layouts and space limitations.

●Scalability:

These units can be expanded or reconfigured as building needs change, making them suitable for both new constructions and retrofits.

●Energy Efficiency:

Many modular air handlers are designed with high-efficiency components, such as variable-speed fans and advanced heat exchangers, to optimize energy consumption.

●Ease of Maintenance:

The modular design often allows for easier access to components, simplifying maintenance and reducing downtime.

 

Applications of Modular Air Handlers

 

Modular air handlers are commonly used in commercial and industrial settings, including:

●Office Buildings: Providing consistent and efficient air distribution across multiple floors.

●Hospitals: Ensuring precise temperature and humidity control in various departments.

●Manufacturing Facilities: Maintaining optimal air quality and temperature for sensitive equipment.

●Educational Institutions: Delivering reliable HVAC solutions for classrooms and auditoriums.

 

image007001
image009001

 (2)(3).jpg

.jpg

(1).jpg

 

 

3

 

 

 

FAQ

 

Q: Where are your products used?

A: Our products are widely used in hospitals, pharmaceutical factories, electronics factories, food factories, hotels, schools, and shopping malls.

Q: What machines do you have in your factory?

A: We have laser cutting machines, high-precision cutting machines, shearing machines, bending machines, high-speed punch presses, welding machines, and edge banding machines.

Q: Do you have a quality inspection department?

A: Yes, we have a quality inspection department with 6 quality inspectors.

Q: Who are your customers?

A: We have worked with well-known brands such as United Laboratories, Sun Yat-sen University, Nanyang Technological University of Singapore, China Central Television, and Beijing West Railway Station.

Q: What was your turnover in 2023?

A: Our turnover in 2023 was approximately 12 million USD.

Q: Do you have a showroom?

A: Yes, we have a showroom that displays our full range of products.

Hot Tags: modular air handler, China modular air handler manufacturers, suppliers, factory, great items, fashionable products, marketable items, innovative items, well-made items, top rated commodities