Overview
Air Handling Units (AHUs) are specialized HVAC systems designed to provide extremely accurate control over temperature, humidity, and air quality. Unlike standard AHUs, precision units are engineered for environments where even minor fluctuations in air parameters could impact operations, equipment performance, or occupant comfort.
Parameter
Cooling, water volume, water resistance
Cooling conditions: Inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃, inlet water temperature 7℃, outlet water temperature 12℃
|
Model |
Two-row pipe |
Four-row pipe |
six-row pipe |
eight-row pipe |
||||||||
|
cooling(KW |
Water volume(m³/h) |
Water resistance (KPa) |
cooling(KW) |
Water volume (m h) |
Water resistance (KPa) |
cooling(kW) |
Water volume (m³/h) |
Water resistance (KPa) |
cooling (KW |
Water volume (m³/h) |
Water resistance (KPa) |
|
|
ZK-05 |
18.8 |
3.23 |
10.1 |
29.4 |
5.01 |
9.76 |
37.8 |
6.49 |
16.99 |
45.7 |
7.85 |
10.44 |
|
ZK-10 |
34.7 |
5.89 |
10.5 |
58.6 |
10.35 |
11.65 |
75.4 |
12.96 |
10.08 |
91.2 |
15.70 |
12.82 |
|
ZK-15 |
53.4 |
9.16 |
9.8 |
87.9 |
15.08 |
7.21 |
113.1 |
19.5 |
12.11 |
136.8 |
23.52 |
15.12 |
|
ZK-20 |
70.6 |
12.14 |
9.8 |
117.3 |
20.16 |
8.25 |
150.8 |
26.21 |
14.07 |
182.4 |
31.96 |
17.48 |
|
ZK-25 |
92.9 |
15.83 |
11.6 |
146.1 |
25.12 |
10.24 |
188.1 |
33.90 |
11.77 |
227.5 |
39.11 |
14.76 |
|
ZK-30 |
113.6 |
19.2 |
11.8 |
175.2 |
30.12 |
11.16 |
225.6 |
38.90 |
13.10 |
273.4 |
47.00 |
16.28 |
|
ZK-40 |
144.4 |
24.82 |
12.4 |
232.8 |
40.03 |
12.93 |
300.2 |
51.61 |
15.73 |
362.2 |
62.27 |
19.20 |
|
ZK-50 |
180.5 |
30.61 |
10.4 |
292.3 |
50.25 |
7.47 |
375.3 |
64.52 |
17.00 |
435.80 |
74.93 |
15.70 |
|
ZK-60 |
216.6 |
37.24 |
9.4 |
349.2 |
60.04 |
7.47 |
450.3 |
77.42 |
17.00 |
544.80 |
93.67 |
15.70 |
|
ZK-80 |
287.2 |
49.1 |
9.1 |
464.6 |
79.88 |
8.5 |
598.4 |
102.89 |
19.5 |
724.8 |
124.62 |
17.9 |
|
ZK-100 |
357.0 |
61.38 |
9.5 |
578.2 |
99.41 |
8.5 |
746.5 |
128.35 |
19.5 |
904.2 |
155.46 |
17.9 |
|
ZK-120 |
428.4 |
73.65 |
9.5 |
693.6 |
118.91 |
8.5 |
895.2 |
153.91 |
19.5 |
1084.8 |
186.51 |
17.9 |
|
ZK-160 |
591.2 |
101.65 |
11.2 |
921.6 |
158.48 |
10.3 |
1190.4 |
204.67 |
20.1 |
1443.2 |
255.93 |
32.4 |
|
ZK-200 |
740.1 |
127.25 |
12.8 |
1152.2 |
199.3 |
13.1 |
1488.1 |
255.86 |
26.4 |
1804.3 |
310.22 |
42.4 |
Note: The performance parameters of the unit at a headwind speed of 2.5m/s
Applications of Industrial AHUs
◆Data centers and server rooms.
◆Pharmaceutical production areas.
◆Cleanrooms in electronics manufacturing.
◆Laboratories and research facilities.
◆High-end healthcare environments.
<
Blower:Blower bearings use lubricated precision ball bearings, and the outer seal ring of the bearing is made of polyamide rubber, which is resistant to high temperatures and can absorb vibration and mechanism noise. The impeller of the purification series air conditioner fan is made of high-quality steel plate (backward-inclined impeller is configured as required), which is more in line with the specific shape of aerodynamics, with high efficiency and low noise.

Surface cooler: The copper tube and aluminum sheet structure is adopted. The copper tube and aluminum sheet are tightly combimechanical or water pressure expansion, and tested by 1.6Mpa air pressure to ensure the minimum contact thermal resistance to achieve the best heat transfer effect. The condensate tray is made of high-quality steel plate or SUS304, double-layer filled with polyurethane foam, and the slope design is more conducive to the discharge of condensate, which has obtained the national patent