Commercial Air Handler Unit
Commercial Air Handler Unit

Commercial Air Handler Unit

A Modular Air Handling Unit (AHU) is a versatile HVAC system designed to provide heating, ventilation, and air conditioning (HVAC) functions in a modular and flexible manner. Unlike traditional AHUs, which are typically large and centralized, modular AHUs consist of individual modules or sections that can be assembled and configured to meet specific project requirements.
Send Inquiry
Overview

 

Commercial Air Handling Unit (AHU) is a central component of large-scale HVAC (Heating, Ventilation, and Air Conditioning) systems, designed to regulate and circulate air in commercial buildings. These units ensure optimal temperature, humidity, and air quality for various applications, including offices, shopping malls, hotels, hospitals, and industrial facilities.

 

Parameter

 

Cooling, water volume, water resistance

 

Cooling conditions: Inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃, inlet water temperature 7℃, outlet water temperature 12℃

Model

Two-row pipe

Four-row pipe

six-row pipe

eight-row pipe

cooling(KW

Water volume(m³/h)

Water resistance (KPa)

cooling(KW)

Water volume (m h)

Water resistance (KPa)

cooling(kW)

Water volume

(m³/h)

Water resistance (KPa)

cooling

(KW

Water volume

(m³/h)

Water resistance (KPa)

ZK-05

18.8

3.23

10.1

29.4

5.01

9.76

37.8

6.49

16.99

45.7

7.85

10.44

ZK-10

34.7

5.89

10.5

58.6

10.35

11.65

75.4

12.96

10.08

91.2

15.70

12.82

ZK-15

53.4

9.16

9.8

87.9

15.08

7.21

113.1

19.5

12.11

136.8

23.52

15.12

ZK-20

70.6

12.14

9.8

117.3

20.16

8.25

150.8

26.21

14.07

182.4

31.96

17.48

ZK-25

92.9

15.83

11.6

146.1

25.12

10.24

188.1

33.90

11.77

227.5

39.11

14.76

ZK-30

113.6

19.2

11.8

175.2

30.12

11.16

225.6

38.90

13.10

273.4

47.00

16.28

ZK-40

144.4

24.82

12.4

232.8

40.03

12.93

300.2

51.61

15.73

362.2

62.27

19.20

ZK-50

180.5

30.61

10.4

292.3

50.25

7.47

375.3

64.52

17.00

435.80

74.93

15.70

ZK-60

216.6

37.24

9.4

349.2

60.04

7.47

450.3

77.42

17.00

544.80

93.67

15.70

ZK-80

287.2

49.1

9.1

464.6

79.88

8.5

598.4

102.89

19.5

724.8

124.62

17.9

ZK-100

357.0

61.38

9.5

578.2

99.41

8.5

746.5

128.35

19.5

904.2

155.46

17.9

ZK-120

428.4

73.65

9.5

693.6

118.91

8.5

895.2

153.91

19.5

1084.8

186.51

17.9

ZK-160

591.2

101.65

11.2

921.6

158.48

10.3

1190.4

204.67

20.1

1443.2

255.93

32.4

ZK-200

740.1

127.25

12.8

1152.2

199.3

13.1

1488.1

255.86

26.4

1804.3

310.22

42.4

 

Note: The performance parameters of the unit at a headwind speed of 2.5m/s

 

Cooling condition correction factor

Correction Factor K1 for Cooling Capacity and Water Flow under Different Inlet Air and Water Temperatures

air temperature

Water temperature

Wet bulb

Temperature

Dry bulb

Temperature

5/10

6/11

7/12

8/13

9/14

17

19-27

0.83

0.76

0.67

0.62

0.57

18

20-30

0.94

1.85

0.76

0.68

0.58

19

21-31

1.07

0.97

0.88

0.79

0.71

19.5

21-33

1.15

1.06

1.00

0.86

0.78

20

22-33

1.20

1.10

1.03

0.90

0.81

21

23-36

1.34

1.24

1.14

1.03

0.93

22

24-39

1.48

1.38

1.28

1.18

1.07

23

25-42

1.63

1.53

1.43

1.32

1.22

24

26-45

1.79

1.69

1.59

1.47

1.36

25

27-48

   

1.75

1.64

1.53

26

28-48

   

1.92

1.81

1.70

27

29-48

   

2.09

1.98

1.87

28

30-50

   

2.26

2.16

2.05

29

31-52

   

2.40

2.32

2.2

 

Correction Factor K3 for Cooling Capacity and Water Flow under Different Inlet Air and Water Temperatures

 

Headwind speed

2.0

2.3

2.5

2.7

3.0

3.3

3.5

coefficient

0.81

0.92

1.0

1.07

1.17

1.26

1.32

Correction Factor K2 for Water Resistance under Different Inlet Air and Water Temperatures

air temperature

Water temperature

Wet bulb

Temperature

Dry bulb

Temperature

5/10

6/11

7/12

8/13

9/14

18

20-30

0.90

0.74

0.60

0.49

0.36

19

21-31

1.13

0.95

0.77

0.65

0.54

19.5

21-33

1.35

1.15

1.00

0.78

0.63

20

22-33

1.41

1.20

1.05

0.82

0.67

21

23-36

1.72

1.49

1.27

1.06

0.86

22

24-39

2.08

1.82

1.57

1.34

1.12

23

25-42

2.48

2.20

1.93

1.66

1.14

24

26-45

2.95

2.62

2.33

2.03

1.76

25

27-48

   

2.78

2.46

2.16

26

28-48

   

3.30

2.94

2.60

27

29-48

   

3.80

3.50

3.12

28

30-50

   

4.14

4.10

3.70

29

31-52

   

4.14

4.10

3.70

 

 

Correction Factor K4 for Water Resistance under Different Inlet Air and Water Temperatures

 

Headwind speed

2.0

2.3

2.5

2.7

3.0

3.3

3.5

coefficient

0.9

0.96

1.0

1.04

1.1

1.16

1.2

Ps:1.The above correction factors are determined based on the average values of various units. For small units (05~15), multiply by 0.95; for large units (50-200), multiply by 1.08.
2.The above correction factors are approximate values and are for reference only.

 

Correction under different wind speeds, inlet air temperature, and water temperature conditions:

Actual cooling capacity = Cooling capacity from Table 1 × K1 × K3
Actual water flow = Water flow from Table 1 × K1 × K3
Actual water resistance = Water resistance from Table 1 × K2 × K4

 

Example: Selecting YG-20 air conditioner, the cooling coil face wind speed is 2.5 m/s. According to Table 1, the cooling capacity is 150.8 kW, water flow is 26.21 m³/h, and water resistance is 14.07 kPa. Determine the actual cooling capacity, water flow, and water resistance when the inlet air dry-bulb temperature is 27°C, wet-bulb temperature is 21°C, inlet water temperature is 7°C, and outlet water temperature is 12°C.

 

Solution: From Table K1, the correction factor K1 = 1.14. From Table K2, the correction factor K2 = 1.27.
Therefore:

Actual cooling capacity (Q) = Standard condition cooling capacity × K1 = 150.8 × 1.14 = 171.91 kW
Actual water flow (V) = Standard condition water flow × K1 = 26.21 × 1.14 = 29.88 m³/h
Actual water resistance (P) = Standard condition water resistance × K2 = 14.07 × 1.27 = 17.87 kPa

 

Heating, water volume, water resistance

Heating conditions: air inlet temperature 15℃, water inlet temperature 60℃

Model

Two-row pipe

four-row pipe

six-row pipe

eight-row pipe

Heating(KW)

Water volume (m/h)

Water resistance (KPa)

Heating

(KW

Water volume

(mh)

Water resistance (KPa)

Heating

(KW)

Water volume

(m³h)

Water resistance

(KPa)

Heating(KW)

Water volume m/h)

Water resistance

(KPa)

ZK-05

34.1

3.23

10.1

50.6

5.01

9.76

59.2

6.49

16.99

77.1

7.85

10.44

ZK-10

67.1

5.89

10.5

99.8

10.35

11.65

124.8

12.96

10.08

151.0

15.70

12.82

ZK-15

101.8

9.16

9.8

149.7

15.08

7.21

173.5

19.5

12.11

205.1

23.52

15.12

ZK-20

135.6

12.14

9.8

199.0

20.16

8.25

248.8

26.21

14.07

289.3

31.96

17.48

ZK-25

168.7

15.83

11.6

249.5

25.12

10.24

311.2

33.90

11.77

353.3

39.11

14.76

ZK-30

202.6

19.2

11.8

304.5

30.12

11.16

380.9

38.90

13.10

448.3

47.00

16.28

ZK-40

270.4

24.82

12.4

399.2

40.03

12.93

480.8

51.61

15.73

592.4

62.27

19.20

ZK-50

337.3

30.61

10.4

512.3

50.25

7.47

556.8

64.52

17.00

641.8

74.93

15.70

ZK-60

404.7

37.24

9.4

609.4

60.04

7.47

581.2

77.42

17.00

766.8

93.67

15.70

ZK-80

539.5

49.1

9.1

796.0

79.88

8.5

386.2

102.89

19.5

1006.0

124.62

17.9

ZK-100

674.5

61.38

9.5

985.1

99.41

8.5

1127.6

128.35

19.5

1272.3

155.46

17.9

ZK-120

808.9

73.65

9.5

1185.9

118.91

8.5

1362.5

153.91

19.5

1533.6

186.51

17.9

ZK-160

1077.8

101.65

11.2

1576.0

158.48

10.3

1688.4

204.67

20.1

2083.2

255.93

32.4

ZK-200

1346.2

127.25

12.8

1970.8

199.3

13.1

2032.7

255.86

26.4

2606.2

310.22

42.4

 

Note: 1. The unit's performance reference at a headwind speed of 2.5m/s
2. The coil is a dual-purpose coil for hot and cold applications

 

Key Features of Modular AHUs

 

 

High-Capacity Airflow Management

Designed to handle large volumes of air efficiently for commercial spaces.

Advanced Filtration System

Equipped with MERV, HEPA, or ULPA filters to remove dust, allergens, and pollutants.

Modular & Customizable Design

Available in various configurations (horizontal, vertical, rooftop, or indoor units) to suit different building requirements.

Energy-Efficient Components

Features variable speed fans, energy recovery wheels, and high-efficiency coils to reduce energy consumption.

Humidity & Temperature Control

Integrated with cooling, heating, and dehumidification functions to maintain comfort levels.

Noise Reduction Technology

Built with insulated panels and vibration dampers for quieter operation.

Smart Control & Monitoring

Can be integrated with Building Management Systems (BMS) for automated climate control.

 

Applications of Modular AHUs

 

🏢 Office Buildings – Ensures employee comfort and improves productivity.
🏬 Shopping Malls & Retail Stores – Maintains a pleasant indoor shopping experience.
🏨 Hotels & Resorts – Provides a comfortable and energy-efficient climate for guests.
🏥 Hospitals & Healthcare Facilities – Ensures sterile, contaminant-free air for critical environments.
🏭 Industrial & Manufacturing Facilities – Supports ventilation and temperature control in factories and warehouses.
🎓 Educational Institutions – Enhances indoor air quality in schools and universities.

 

image007001
image009001

 (2)(3).jpg

.jpg

(1).jpg

 

 

3

 

 

 

FAQ

 

Q: Where are your products used?

A: Our products are widely used in hospitals, pharmaceutical factories, electronics factories, food factories, hotels, schools, and shopping malls.

Q: What machines do you have in your factory?

A: We have laser cutting machines, high-precision cutting machines, shearing machines, bending machines, high-speed punch presses, welding machines, and edge banding machines.

Q: Do you have a quality inspection department?

A: Yes, we have a quality inspection department with 6 quality inspectors.

Q: Who are your customers?

A: We have worked with well-known brands such as United Laboratories, Sun Yat-sen University, Nanyang Technological University of Singapore, China Central Television, and Beijing West Railway Station.

Q: What was your turnover in 2023?

A: Our turnover in 2023 was approximately 12 million USD.

Q: Do you have a showroom?

A: Yes, we have a showroom that displays our full range of products.

Hot Tags: commercial air handler unit, China commercial air handler unit manufacturers, suppliers, factory, nice items, efficient products, wonderful products, durable products, eye catching products, long-lasting items