Floor Convector Radiators
Floor Convector Radiators

Floor Convector Radiators

Industrial Floor Convector is a robust heating unit designed for use in industrial settings such as warehouses, factories, workshops, and other large-scale facilities. These convectors are engineered to provide efficient and powerful heating to withstand the demanding conditions of industrial environments. Industrial floor convectors are typically installed flush with the floor surface or mounted on the surface, offering versatile heating solutions for various industrial applications while maximizing space efficiency.
Send Inquiry
Overview

 

Floor convector radiators are a modern and efficient heating solution designed to provide comfortable indoor temperatures while maintaining a sleek and unobtrusive aesthetic. Installed at or slightly below floor level, these radiators use the principle of convection to circulate warm air throughout a space. They are especially popular in buildings with large windows or areas where wall-mounted radiators are not practical.

 

Parameter

 

AHK340/150 Double pipe type

Model

AHK340/150-1250

AHK340/150-2000

AHK340/150-2750

Speed level

3

2

1

3

2

1

3

2

1

Air flowm³h

287

197

105

574

394

210

861

591

315

Sound pressure level dB(A)

37

25

20

39

27

21

40

28

22

Power level(W

46

32

18

92

64

36

138

96

54

Number of motors

1

2

3

Water temperature(c

room temperature(C)

Heating capacity(W)

Heating capacity(W

Heating capacity(W)

95/70

18

4949

3575

2548

9713

7014

4997

14427

10390

7403

20

4796

3464

2470

5412

6796

4842

13980

10067

7173

80/60

18

3990

2882

2055

7830

5654

4028

11630

8375

5967

20

3837

2771

1976

7529

5436

3874

11183

8053

5738

75/60

18

3798

2743

1956

7454

5382

3835

11070

7972

5680

20

3644

2633

1877

7152

5164

3679

10623

7650

5450

70/55

18

3415

2466

1758

6701

4838

3447

9951

7167

5107

20

3261

2355

1679

6399

4621

3292

9504

6845

4877

60/45

18

2647

1912

1363

5194

3750

2672

7715

5556

3958

20

2493

1801

1283

4892

3533

2517

7268

5234

3729

Water temperature(℃)

room temperature(C)

Heating capacity(w)

Heating capacity(W

Heating capacity(W)

6/12

26

Qk

1434

1036

739

2814

2032

1448

4180

3010

2145

Qs

1205

870

621

2364

1707

1217

3512

2529

1802

24

Qk

1121

809

577

2198

1587

1131

3264

2351

1675

Qs

1084

783

558

2127

1536

1094

3159

2275

1621

8/14

26

Qk

1084

783

558

2127

1536

1094

3159

2275

1621

Qs

1084

783

558

2127

1536

1094

3159

2275

1621

24

Qk

873

630

449

'712

1237

881

2543

1832

1305

Qs

873

630

449

712

1237

881

2543

1832

1305

10/15

26

Qk

890

644

459

.747

1262

899

2595

1868

1331

Qs

890

644

459

747

1262

899

2595

1868

1331

24

Qk

764

552

393

-499

1082

771

2226

1603

1142

Qs

764

552

393

1499

1082

771

2226

1603

1142

12/16

26

Qk

782

565

403

535

1108

789

2279

1641

1169

Qs

782

565

403

1535

1108

789

2279

1641

1169

24

Qk

659

476

339

292

933

665

1919

1382

985

Qs

749

476

339

292

933

665

1919

1382

985

16/18

26

Qk

576

417

297

130

816

582

1679

1210

862

Qs

576

417

297

1130

816

582

1679

1210

862

24

Qk

469

338

241

920

664

473

366

984

701

Qs

469

338

241

920

664

473

1366

984

701

The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity

 

AHK340/150 four pipe type

Model

AHK340/150-1250

AHK340/150-2000

AHK340/150-2750

Speed level

3

2

1

3

2

1

3 2

1

Air flow m³h

287

197

105

574

394

210

861 591

315

Sound pressure level dB(A)

37

25

20

29

27

21

40 28

22

Power level(W

46

32

18

92

64

36

138 96

54

Number of motors

1

2

3

Water temperature(c

room temperature(C)

Heating capacity(W)

Heating capacity(W

Heating capacity(W)

95/70

18

2870

2074

147

5633

4068

2898

8367 6026

4294

20

2782

2009

1433

5459

3942

2808

8108 5839

4161

80/60

18

2314

1671

1192

4541

3280

2336

6746 4858

3461

20

2226

1607

1146

4367

3153

2246

6486 4671

3328

75/60

18

2203

1591

1134

4324

3121

2224

6421 4624

3294

20

2113

1527

1088

4148

2995

2134

6161 4437

3161

70/55

18

1981

1430

1020

3886

2806

1999

5772 4157

2962

20

1891

1366

974

3712

2680

1910

5513 3970

2829

60/45

18

1535

1109

790

3012

2175

1550

4475 3222

2296

20

1446

1045

744

2838

2049

1460

4216 3036

2163

Water temperature(c

room temperature(C)

Heating capacity(W)

Heating capacity(W

Heating capacity(W)

6/12

26

Qk

1147

829

591

2252

1625

1158

3344

2408

1715

Qs

964

697

497

1892

1366

974

2810

2023

1442

24

Qk

896

647

462

1759

1269

905

2612

1881

1340

Qs

867

626

445

1701

1229

876

2527

1820

1297

8/14

26

Qk

867

626

446

1701

1229

876

2527

1820

1297

Qs

867

626

446

1701

1229

876

2527

1820

1297

24

Qk

698

504

359

1370

989

705

2034

1465

1044

Qs

698

504

359

1370

989

705

2034

1465

1044

10/15

26

Qk

712

515

367

1398

1010

719

2075

1495

1065

Qs

712

515

367

1398

1010

719

2075

1495

1065

24

Qk

611

441

315

1199

866

617

1780

1283

914

Qs

611

441

315

1199

866

617

1780

1283

914

12/16

26

Qk

626

452

322

1228

887

632

1823

1312

935

Qs

626

452

322

1228

887

632

1823

1312

935

24

Qk

527

381

272

1034

747

532

1535

1106

788

Qs

527

381

272

1034

747

532

1535

1106

788

16/18

26

Qk

461

333

238

905

653

466

1344

968

689

Qs

461

333

238

905

653

466

1344

968

689

24

Qk

375

271

193

736

531

379

1093

787

561

Qs

375

271

193

736

531

379

1093

787

561

The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity

 

 
Natural convection type
b8689f50200096ea855a533a5d7e2a2.png
 
Cooling and heating type
98723cad019d62b77fac095d291b113.png
Advantages of Floor Convector Radiators

◆Space-Saving Design: Installed flush with the floor, they free up wall space for furniture or décor.

◆Enhanced Aesthetics: Discreet and low-profile, they seamlessly blend into the surrounding environment.

◆Efficient Heating: Provides even heat distribution without creating cold spots.

◆Prevents Cold Drafts: Especially effective when placed near large windows to counteract heat loss.

◆Safe and Child-Friendly: The heating surface is typically not exposed, making it safer for households with children or pets.

◆Energy Efficient: Consumes less energy compared to traditional radiators, especially when equipped with smart thermostatic controls.

◆Flexible Installation: Available in various sizes and configurations to fit different room layouts.

 

Applications of Floor Convector Radiators

 

 

Floor convector radiators are highly versatile and ideal for a wide range of applications:

◆Residential Spaces

Perfect for modern homes, apartments, and townhouses, especially in rooms with large glass windows or patio doors.

◆Commercial Buildings

Suitable for office spaces, retail stores, and showrooms where maintaining a clean aesthetic is important.

◆Conservatories and Sunrooms

Prevents cold air from entering by counteracting heat loss around windows.

◆Lobbies and Reception Areas

Commonly installed in hotels, airports, and commercial buildings to maintain a warm and welcoming atmosphere.

◆Healthcare and Educational Facilities

Used in hospitals, clinics, and schools where safety, comfort, and hygiene are key.

◆Industrial Spaces

Provides efficient heating in warehouses, factories, and other large, open environments.

.jpg

.jpg

(1).jpg

 

 

product-907-456

 

 

 

FAQ

 

Q: Are you a trading company or a manufacturer?

A: We are a professional manufacturer of air conditioning boxes, fan coil units, and floor convectors. We directly trade our products with customers.

Q: What are your delivery terms?

A: Our regular delivery term is FOB Shanghai. We also accept EXW, CFR, CIF, DDP, DDU, etc. We will provide you with the freight, and you can choose the most convenient and effective one for you.

Q: When can I get the quotation?

A: We usually provide a quotation within 24 hours after receiving your inquiry. If you urgently need the price information, please let us know so that we can prioritize your inquiry.

Q: What are your main markets?

A: Our main markets include Europe, North America, South America, Australia, and Southeast Asia.

Q: How large is your factory?

A: Our factory covers an area of over 60,000 square meters.

Q: What was your turnover in 2023?

A: Our turnover in 2023 was approximately 12 million USD.

Q: Do you have a showroom?

A: Yes, we have a showroom that displays our full range of products.

Hot Tags: floor convector radiators, China floor convector radiators manufacturers, suppliers, factory, useful items, sturdy commodities, exclusive commodities, latest items, popular commodities, high quality products