Overview
floor fan convector is a type of heating and cooling unit designed to be installed at floor level, often recessed into the floor or positioned along walls. Unlike traditional radiators or heating systems, floor fan convectors use a fan-assisted mechanism to circulate air over a heating or cooling coil, providing efficient and consistent temperature control.
These units are ideal for spaces where aesthetics and space optimization are priorities, offering both functional and design benefits.
Parameter
AHK340/150 Double pipe type
|
Model |
AHK340/150-1250 |
AHK340/150-2000 |
AHK340/150-2750 |
||||||||
|
Speed level |
3 |
2 |
1 |
3 |
2 |
1 |
3 |
2 |
1 |
||
|
Air flowm³h |
287 |
197 |
105 |
574 |
394 |
210 |
861 |
591 |
315 |
||
|
Sound pressure level dB(A) |
37 |
25 |
20 |
39 |
27 |
21 |
40 |
28 |
22 |
||
|
Power level(W |
46 |
32 |
18 |
92 |
64 |
36 |
138 |
96 |
54 |
||
|
Number of motors |
1 |
2 |
3 |
||||||||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
95/70 |
18 |
4949 |
3575 |
2548 |
9713 |
7014 |
4997 |
14427 |
10390 |
7403 |
|
|
20 |
4796 |
3464 |
2470 |
5412 |
6796 |
4842 |
13980 |
10067 |
7173 |
||
|
80/60 |
18 |
3990 |
2882 |
2055 |
7830 |
5654 |
4028 |
11630 |
8375 |
5967 |
|
|
20 |
3837 |
2771 |
1976 |
7529 |
5436 |
3874 |
11183 |
8053 |
5738 |
||
|
75/60 |
18 |
3798 |
2743 |
1956 |
7454 |
5382 |
3835 |
11070 |
7972 |
5680 |
|
|
20 |
3644 |
2633 |
1877 |
7152 |
5164 |
3679 |
10623 |
7650 |
5450 |
||
|
70/55 |
18 |
3415 |
2466 |
1758 |
6701 |
4838 |
3447 |
9951 |
7167 |
5107 |
|
|
20 |
3261 |
2355 |
1679 |
6399 |
4621 |
3292 |
9504 |
6845 |
4877 |
||
|
60/45 |
18 |
2647 |
1912 |
1363 |
5194 |
3750 |
2672 |
7715 |
5556 |
3958 |
|
|
20 |
2493 |
1801 |
1283 |
4892 |
3533 |
2517 |
7268 |
5234 |
3729 |
||
|
Water temperature(℃) |
room temperature(C) |
Heating capacity(w) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
6/12 |
26 |
Qk |
1434 |
1036 |
739 |
2814 |
2032 |
1448 |
4180 |
3010 |
2145 |
|
Qs |
1205 |
870 |
621 |
2364 |
1707 |
1217 |
3512 |
2529 |
1802 |
||
|
24 |
Qk |
1121 |
809 |
577 |
2198 |
1587 |
1131 |
3264 |
2351 |
1675 |
|
|
Qs |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
||
|
8/14 |
26 |
Qk |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
|
Qs |
1084 |
783 |
558 |
2127 |
1536 |
1094 |
3159 |
2275 |
1621 |
||
|
24 |
Qk |
873 |
630 |
449 |
'712 |
1237 |
881 |
2543 |
1832 |
1305 |
|
|
Qs |
873 |
630 |
449 |
712 |
1237 |
881 |
2543 |
1832 |
1305 |
||
|
10/15 |
26 |
Qk |
890 |
644 |
459 |
.747 |
1262 |
899 |
2595 |
1868 |
1331 |
|
Qs |
890 |
644 |
459 |
747 |
1262 |
899 |
2595 |
1868 |
1331 |
||
|
24 |
Qk |
764 |
552 |
393 |
-499 |
1082 |
771 |
2226 |
1603 |
1142 |
|
|
Qs |
764 |
552 |
393 |
1499 |
1082 |
771 |
2226 |
1603 |
1142 |
||
|
12/16 |
26 |
Qk |
782 |
565 |
403 |
535 |
1108 |
789 |
2279 |
1641 |
1169 |
|
Qs |
782 |
565 |
403 |
1535 |
1108 |
789 |
2279 |
1641 |
1169 |
||
|
24 |
Qk |
659 |
476 |
339 |
292 |
933 |
665 |
1919 |
1382 |
985 |
|
|
Qs |
749 |
476 |
339 |
292 |
933 |
665 |
1919 |
1382 |
985 |
||
|
16/18 |
26 |
Qk |
576 |
417 |
297 |
130 |
816 |
582 |
1679 |
1210 |
862 |
|
Qs |
576 |
417 |
297 |
1130 |
816 |
582 |
1679 |
1210 |
862 |
||
|
24 |
Qk |
469 |
338 |
241 |
920 |
664 |
473 |
366 |
984 |
701 |
|
|
Qs |
469 |
338 |
241 |
920 |
664 |
473 |
1366 |
984 |
701 |
||
|
The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity |
|||||||||||
AHK340/150 four pipe type
|
Model |
AHK340/150-1250 |
AHK340/150-2000 |
AHK340/150-2750 |
||||||||
|
Speed level |
3 |
2 |
1 |
3 |
2 |
1 |
3 2 |
1 |
|||
|
Air flow m³h |
287 |
197 |
105 |
574 |
394 |
210 |
861 591 |
315 |
|||
|
Sound pressure level dB(A) |
37 |
25 |
20 |
29 |
27 |
21 |
40 28 |
22 |
|||
|
Power level(W |
46 |
32 |
18 |
92 |
64 |
36 |
138 96 |
54 |
|||
|
Number of motors |
1 |
2 |
3 |
||||||||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
95/70 |
18 |
2870 |
2074 |
147 |
5633 |
4068 |
2898 |
8367 6026 |
4294 |
||
|
20 |
2782 |
2009 |
1433 |
5459 |
3942 |
2808 |
8108 5839 |
4161 |
|||
|
80/60 |
18 |
2314 |
1671 |
1192 |
4541 |
3280 |
2336 |
6746 4858 |
3461 |
||
|
20 |
2226 |
1607 |
1146 |
4367 |
3153 |
2246 |
6486 4671 |
3328 |
|||
|
75/60 |
18 |
2203 |
1591 |
1134 |
4324 |
3121 |
2224 |
6421 4624 |
3294 |
||
|
20 |
2113 |
1527 |
1088 |
4148 |
2995 |
2134 |
6161 4437 |
3161 |
|||
|
70/55 |
18 |
1981 |
1430 |
1020 |
3886 |
2806 |
1999 |
5772 4157 |
2962 |
||
|
20 |
1891 |
1366 |
974 |
3712 |
2680 |
1910 |
5513 3970 |
2829 |
|||
|
60/45 |
18 |
1535 |
1109 |
790 |
3012 |
2175 |
1550 |
4475 3222 |
2296 |
||
|
20 |
1446 |
1045 |
744 |
2838 |
2049 |
1460 |
4216 3036 |
2163 |
|||
|
Water temperature(c |
room temperature(C) |
Heating capacity(W) |
Heating capacity(W |
Heating capacity(W) |
|||||||
|
6/12 |
26 |
Qk |
1147 |
829 |
591 |
2252 |
1625 |
1158 |
3344 |
2408 |
1715 |
|
Qs |
964 |
697 |
497 |
1892 |
1366 |
974 |
2810 |
2023 |
1442 |
||
|
24 |
Qk |
896 |
647 |
462 |
1759 |
1269 |
905 |
2612 |
1881 |
1340 |
|
|
Qs |
867 |
626 |
445 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
||
|
8/14 |
26 |
Qk |
867 |
626 |
446 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
|
Qs |
867 |
626 |
446 |
1701 |
1229 |
876 |
2527 |
1820 |
1297 |
||
|
24 |
Qk |
698 |
504 |
359 |
1370 |
989 |
705 |
2034 |
1465 |
1044 |
|
|
Qs |
698 |
504 |
359 |
1370 |
989 |
705 |
2034 |
1465 |
1044 |
||
|
10/15 |
26 |
Qk |
712 |
515 |
367 |
1398 |
1010 |
719 |
2075 |
1495 |
1065 |
|
Qs |
712 |
515 |
367 |
1398 |
1010 |
719 |
2075 |
1495 |
1065 |
||
|
24 |
Qk |
611 |
441 |
315 |
1199 |
866 |
617 |
1780 |
1283 |
914 |
|
|
Qs |
611 |
441 |
315 |
1199 |
866 |
617 |
1780 |
1283 |
914 |
||
|
12/16 |
26 |
Qk |
626 |
452 |
322 |
1228 |
887 |
632 |
1823 |
1312 |
935 |
|
Qs |
626 |
452 |
322 |
1228 |
887 |
632 |
1823 |
1312 |
935 |
||
|
24 |
Qk |
527 |
381 |
272 |
1034 |
747 |
532 |
1535 |
1106 |
788 |
|
|
Qs |
527 |
381 |
272 |
1034 |
747 |
532 |
1535 |
1106 |
788 |
||
|
16/18 |
26 |
Qk |
461 |
333 |
238 |
905 |
653 |
466 |
1344 |
968 |
689 |
|
Qs |
461 |
333 |
238 |
905 |
653 |
466 |
1344 |
968 |
689 |
||
|
24 |
Qk |
375 |
271 |
193 |
736 |
531 |
379 |
1093 |
787 |
561 |
|
|
Qs |
375 |
271 |
193 |
736 |
531 |
379 |
1093 |
787 |
561 |
||
|
The length of the heat dissipation element of all models in the table is L-250mm. In addition to the above standard models, our company can customize them according to the specific building and heat dissipation requirements. Qk-total cooling capacity; Qs: sensible cooling capacity |
|||||||||||


Advantages of Floor Fan Convector
◆Quick Heating and Cooling: The fan ensures rapid temperature adjustment, making these units more efficient than traditional radiators.
◆Energy Efficiency: They consume less energy by delivering heat or cool air directly to the space where it's needed.
◆Space-Saving Design: Installed at floor level or recessed into the floor, floor fan convectors free up wall and ceiling space.
◆Even Air Distribution: The fan ensures uniform temperature control, reducing cold spots.
◆Aesthetic Flexibility: Available in various sizes, styles, and grille finishes to match interior decor.
◆Silent Operation: Many models offer low-noise fan settings for a quieter environment.
Applications of Floor Fan Convector
Floor fan convectors are widely used in various settings due to their space-saving design and efficient performance:
◆Residential Spaces
Suitable for living rooms, bedrooms, and sunrooms where maintaining a comfortable indoor environment is essential.
◆Commercial Buildings
Used in offices, hotels, restaurants, and retail stores to ensure effective temperature control.
◆Public Spaces
Frequently installed in museums, libraries, and galleries where aesthetics are crucial, and wall space is limited.
◆Conservatories and Glass-Walled Areas
Ideal for areas with large windows or glass facades to counteract heat loss during winter.
◆Educational and Healthcare Facilities
Installed in schools, universities, hospitals, and clinics for reliable and efficient heating or cooling.




FAQ
Q: What is your delivery time?
Q: What are your payment terms?
Q: What payment methods do you accept?
essaging methods to avoid any delays.
Q: What are your delivery terms?
Q: Question:What are your payment methods?
2,Design Manufacturing) and OEM (Original Equipment Manufacturing) orders: We require a 30% deposit and the remaining 70% as the balance payment.
Q: Where is your factory located?
Hot Tags: floor fan convector, China floor fan convector manufacturers, suppliers, factory, stylish items, quality commodities, impressive products, outstanding items, quality products, engaging items