Overview
The Industrial Air Handling Unit is a critical equipment in industrial environments, used for air handling and maintaining indoor environmental comfort and suitability. These units are typically employed in large industrial facilities such as factories, workshops, and warehouses, with designs and functionalities tailored to meet the specific requirements and challenges of industrial settings.
Parameter
Cooling, water volume, water resistance
Cooling conditions: Inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃, inlet water temperature 7℃, outlet water temperature 12℃
|
Model |
Two-row pipe |
Four-row pipe |
six-row pipe |
eight-row pipe |
||||||||
|
cooling(KW |
Water volume(m³/h) |
Water resistance (KPa) |
cooling(KW) |
Water volume (m h) |
Water resistance (KPa) |
cooling(kW) |
Water volume (m³/h) |
Water resistance (KPa) |
cooling (KW |
Water volume (m³/h) |
Water resistance (KPa) |
|
|
ZK-05 |
18.8 |
3.23 |
10.1 |
29.4 |
5.01 |
9.76 |
37.8 |
6.49 |
16.99 |
45.7 |
7.85 |
10.44 |
|
ZK-10 |
34.7 |
5.89 |
10.5 |
58.6 |
10.35 |
11.65 |
75.4 |
12.96 |
10.08 |
91.2 |
15.70 |
12.82 |
|
ZK-15 |
53.4 |
9.16 |
9.8 |
87.9 |
15.08 |
7.21 |
113.1 |
19.5 |
12.11 |
136.8 |
23.52 |
15.12 |
|
ZK-20 |
70.6 |
12.14 |
9.8 |
117.3 |
20.16 |
8.25 |
150.8 |
26.21 |
14.07 |
182.4 |
31.96 |
17.48 |
|
ZK-25 |
92.9 |
15.83 |
11.6 |
146.1 |
25.12 |
10.24 |
188.1 |
33.90 |
11.77 |
227.5 |
39.11 |
14.76 |
|
ZK-30 |
113.6 |
19.2 |
11.8 |
175.2 |
30.12 |
11.16 |
225.6 |
38.90 |
13.10 |
273.4 |
47.00 |
16.28 |
|
ZK-40 |
144.4 |
24.82 |
12.4 |
232.8 |
40.03 |
12.93 |
300.2 |
51.61 |
15.73 |
362.2 |
62.27 |
19.20 |
|
ZK-50 |
180.5 |
30.61 |
10.4 |
292.3 |
50.25 |
7.47 |
375.3 |
64.52 |
17.00 |
435.80 |
74.93 |
15.70 |
|
ZK-60 |
216.6 |
37.24 |
9.4 |
349.2 |
60.04 |
7.47 |
450.3 |
77.42 |
17.00 |
544.80 |
93.67 |
15.70 |
|
ZK-80 |
287.2 |
49.1 |
9.1 |
464.6 |
79.88 |
8.5 |
598.4 |
102.89 |
19.5 |
724.8 |
124.62 |
17.9 |
|
ZK-100 |
357.0 |
61.38 |
9.5 |
578.2 |
99.41 |
8.5 |
746.5 |
128.35 |
19.5 |
904.2 |
155.46 |
17.9 |
|
ZK-120 |
428.4 |
73.65 |
9.5 |
693.6 |
118.91 |
8.5 |
895.2 |
153.91 |
19.5 |
1084.8 |
186.51 |
17.9 |
|
ZK-160 |
591.2 |
101.65 |
11.2 |
921.6 |
158.48 |
10.3 |
1190.4 |
204.67 |
20.1 |
1443.2 |
255.93 |
32.4 |
|
ZK-200 |
740.1 |
127.25 |
12.8 |
1152.2 |
199.3 |
13.1 |
1488.1 |
255.86 |
26.4 |
1804.3 |
310.22 |
42.4 |
Note: The performance parameters of the unit at a headwind speed of 2.5m/s
Key Features of Industrial AHUs
- Durability and Robustness:
Industrial Air Handling Units are constructed with sturdy and durable materials and structures, capable of withstanding harsh conditions and high-intensity usage in industrial environments.
- Efficient Filtration and Purification:
Equipped with powerful filtration systems, these units can remove particles, dust, smoke, and pollutants from the air, ensuring clean and healthy indoor air quality.
- Temperature and Humidity Control:
Industrial AHUs possess strong cooling and heating capabilities, enabling rapid adjustment of indoor temperature and humidity to ensure stability and efficiency in industrial production processes.
- Adaptability and Flexibility:
These units typically offer flexible configuration options, allowing for customization and adjustment based on specific industrial requirements to meet the needs of different production environments.
- Energy Efficiency and Environmental Sustainability:
Industrial AHUs incorporate advanced energy-saving technologies and equipment such as high-efficiency filters, heat recovery systems, and intelligent control systems to reduce energy consumption and minimize environmental impact.
- Safety and Reliability:
Designed with high levels of safety and reliability, these units comply with industrial safety standards and maintain stable operation under various working conditions.
Industrial AHUs are deployed across sectors that require strict environmental control:
🏭 Pharmaceutical Plants
⚗️ Chemical Processing Facilities
🍖 Food and Beverage Manufacturing
🧪 Laboratories and Cleanrooms
🏗️ Steel and Cement Plants
🔋 Battery and Electronics Factories
🚗 Automotive Assembly Lines
🛫 Aerospace and Defense Production
Each of these applications has unique air treatment needs, such as humidity regulation, VOC control, pressurization, or hygiene compliance.
Blower:Blower bearings use lubricated precision ball bearings, and the outer seal ring of the bearing is made of polyamide rubber, which is resistant to high temperatures and can absorb vibration and mechanism noise. The impeller of the purification series air conditioner fan is made of high-quality steel plate (backward-inclined impeller is configured as required), which is more in line with the specific shape of aerodynamics, with high efficiency and low noise.

Surface cooler: The copper tube and aluminum sheet structure is adopted. The copper tube and aluminum sheet are tightly combimechanical or water pressure expansion, and tested by 1.6Mpa air pressure to ensure the minimum contact thermal resistance to achieve the best heat transfer effect. The condensate tray is made of high-quality steel plate or SUS304, double-layer filled with polyurethane foam, and the slope design is more conducive to the discharge of condensate, which has obtained the national patent





FAQ
Q: Where is your factory located?
Q: When was your factory established?
Q: What are your main markets?
Q: How large is your factory?
Q: How many workers are there in your factory?
Hot Tags: industrial ahu, China industrial ahu manufacturers, suppliers, factory, exclusive items, eye-catching items, latest items, popular products, reliable commodities, useful products