roof-mounted air handling unit (AHU) is a type of HVAC equipment designed to be installed on the roof of commercial or industrial buildings. Like other AHUs, it is responsible for circulating and conditioning air-including ventilation, filtration, heating, and cooling-but what makes it unique is that it operates outdoors, freeing up interior space.
Roof-mounted AHUs are an essential choice for buildings with limited indoor mechanical space, offering powerful performance in a compact, weatherproof design.
Parameter
|
Air Volume
|
Residual pressure |
Cooling(KW) |
Heat ( K W) |
Water Volume (T/h) |
Water Resistance(KPa) |
Power |
Noise |
Weight |
|||||
|
Return Air |
Fresh Air |
Return Air |
Fresh Air |
Return Air |
Fresh Air |
Return Air |
Fresh Air |
||||||
|
BFP-20W/L |
2000 |
200 |
11.2 |
22.5 |
19.1 |
28.00 |
1.9 |
3.9 |
3.5 |
4.2 |
0.32 |
55 |
140/160 |
|
BFP-20XW/L |
160 |
13.9 |
29.7 |
25.7 |
32.67 |
2.4 |
5.1 |
4.5 |
5.6 |
160/190 |
|||
|
BFP-30W/L |
3000 |
260 |
16.8 |
33.8 |
28.6 |
42.00 |
2.9 |
5.8 |
4.5 |
6.4 |
0.55 |
56 |
160/180 |
|
BFP-30XW/L |
220 |
20.8 |
44.5 |
38.5 |
49.00 |
3.6 |
7.7 |
5.3 |
8.5 |
180/210 |
|||
|
BFP-40W/L |
4000 |
340 |
22.4 |
45.1 |
38.1 |
56.00 |
3.9 |
7.7 |
4.6 |
6.7 |
0.75 |
58 |
195/220 |
|
BFP.40XW/ |
300 |
27.7 |
59.3 |
513 |
64.33 |
4.8 |
10.2 |
6.5 |
12.4 |
225/255 |
|||
|
BFP-45W/L |
4500 |
320 |
25.2 |
50.7 |
42.9 |
63.00 |
4.3 |
8.7 |
5.2 |
8.6 |
0.75 |
58 |
205/220 |
|
BFP-45XW/L |
280 |
31.2 |
66.8 |
57.8 |
73.50 |
5.4 |
11.5 |
7.4 |
15.4 |
215/235 |
|||
|
BFP-50W/L |
5000 |
500 |
28.0 |
56.3 |
47.7 |
70.00 |
4.8 |
9.7 |
6.8 |
10.7 |
1.1 |
59 |
220/235 |
|
BFP-50XW/L |
460 |
34.7 |
74.2 |
64.2 |
81.67 |
6.0 |
12.8 |
8.1 |
19.5 |
230/255 |
|||
|
BFP-55W/L |
5500 |
500 |
30.8 |
62.0 |
52.4 |
77.00 |
5.3 |
10.7 |
6.5 |
12.7 |
1.5 |
59 |
238/256 |
|
BFP-55XW/L |
460 |
38.1 |
81.6 |
70.6 |
89.83 |
6.6 |
14.0 |
9.5 |
20.3 |
256/286 |
|||
|
BFP-60W/L |
6000 |
500 |
33.6 |
67.6 |
57.2 |
84.00 |
5.8 |
11.6 |
7.4 |
14.8 |
1.5 |
60 |
258/285 |
|
BFP-60XW/L |
460 |
41.6 |
89.0 |
77.0 |
98.00 |
7.2 |
15.3 |
11.3 |
28.2 |
285/306 |
|||
|
BFP-70W/L |
7000 |
500 |
39.2 |
78.9 |
66.7 |
98.00 |
6.7 |
13.6 |
8.5 |
16.5 |
1.8 |
61 |
282/312 |
|
BFP-70XW/L |
460 |
48.5 |
103.8 |
89.8 |
114.33 |
8.3 |
17.9 |
14.6 |
33.3 |
315/346 |
|||
|
BFP-80W/L |
8000 |
600 |
44.8 |
90.1 |
76.3 |
112.00 |
7.7 |
15.5 |
9.06 |
18.4 |
2.2 |
62 |
310/345 |
|
BFP-80XW/L |
560 |
55.5 |
118.7 |
102.7 |
130.67 |
9.5 |
20.4 |
16.4 |
39.6 |
338/369 |
|||
|
BFP-90W/L |
9000 |
600 |
50.4 |
101.4 |
85.8 |
126.00 |
8.7 |
17.4 |
10.6 |
22.4 |
2.2 |
63 |
322/358 |
|
BFP-90XW/L |
560 |
62.4 |
133.5 |
115.5 |
147.00 |
10.7 |
23.0 |
18.2 |
43.6 |
345/369 |
|||
|
BFP-100W/L |
10000 |
600 |
56.0 |
112.7 |
95.3 |
140.00 |
9.6 |
19.4 |
12.4 |
26.7 |
3.0 |
64 |
336/368 |
|
BFP-100XW/L |
560 |
69.3 |
148.3 |
128.3 |
163.33 |
11.9 |
25.5 |
21.6 |
48.6 |
356/389 |
|||
|
BFP-120W/L |
12000 |
600 |
67.2 |
135.2 |
114.4 |
168.00 |
11.6 |
23.2 |
18.7 |
40.1 |
1.8×2 |
64 |
438/475 |
|
BFP-120XW/L |
560 |
83.2 |
178.0 |
154.0 |
196.00 |
14.3 |
30.6 |
28.4 |
53.2 |
476/506 |
|||
|
BFP-150W/L |
15000 |
600 |
84.0 |
169.0 |
143.0 |
210.00 |
14.4 |
29.1 |
22.6 |
42.6 |
2.2×2 |
64 |
520/55 |
|
BFP-150XW/L |
560 |
104.0 |
222.5 |
192.5 |
245.00 |
17.9 |
38.3 |
35.7 |
73.5 |
562/598 |
|||
|
BFP-180W/L |
18000 |
600 |
100.8 |
202.8 |
171.6 |
252.00 |
17.3 |
34.9 |
25.1 |
44.2 |
3.0×2 |
65 |
556/581 |
|
BFP-180XW/L |
560 |
124.8 |
267.0 |
231.0 |
294.00 |
21.5 |
45.9 |
47.6 |
78.2 |
585/615 |
|||
|
BFP-200W/L |
20000 |
600 |
112.0 |
225.3 |
190.7 |
280.00 |
19.3 |
38.7 |
28.7 |
46.5 |
3.0×2 |
65 |
576/595 |
|
BFP-200XW/L |
560 |
138.7 |
296.7 |
256.7 |
326.67 |
23.8 |
51.0 |
51.6 |
82.6 |
610/638 |
|||
|
BFP-230W/L |
23000 |
650 |
128.8 |
259.1 |
219.3 |
322.00 |
22.1 |
44.6 |
29.7 |
48.7 |
4.0×2 |
68 |
612/635 |
|
BFP-230XWL |
600 |
159.5 |
341.2 |
295.2 |
375.67 |
27.4 |
58.7 |
51.6 |
85.2 |
639/672 |
|||
|
BFP-250W/ |
25000 |
650 |
140.0 |
281.7 |
238.3 |
350.00 |
24.1 |
48.4 |
26.5 |
49.6 |
4.0×2 |
69 |
652/685 |
|
BFP-250XW/L |
600 |
173.3 |
370.8 |
320.8 |
408.33 |
29.8 |
63.8 |
50.2 |
82.6 |
710/732 |
|||
|
BFP-280W/L |
28000 |
650 |
156.8 |
315.5 |
266.9 |
392.00 |
27.0 |
54.2 |
32.6 |
43.6 |
5.5×2 |
70 |
679/712 |
|
BFP-280XW/L |
600 |
194.1 |
415.3 |
359.3 |
457.33 |
33.4 |
71.4 |
54.5 |
92.5 |
729/758 |
|||
|
BFP-300W/L |
30000 |
650 |
168.0 |
338.0 |
286.0 |
420.00 |
28.9 |
58.1 |
36.9 |
52.3 |
5.5×2 |
70 |
712/735 |
|
BFP-300XW/L |
600 |
208.0 |
445.0 |
385.0 |
490.00 |
35.8 |
76.5 |
57.2 |
91.2 |
765/796 |
|||
|
BFP-350W/ |
35000 |
650 |
196.0 |
394.3 |
333.7 |
490.00 |
33.7 |
67.8 |
38.7 |
59.4 |
7.5×2 |
72 |
826/998 |
|
BFP-350XW/L |
600 |
242.7 |
519.2 |
449.2 |
571.67 |
41.7 |
89.3 |
58.7 |
96.2 |
910/1110 |
|||
Key Features of Ceiling Mounted AHUs
- Space-saving Design: Ceiling-mounted AHUs are designed to be compact and lightweight, allowing them to be installed in areas with limited space, such as offices, retail stores, and classrooms.
- Discreet Installation: These units are installed above false ceilings or suspended from the ceiling, keeping them out of sight and minimizing visual impact on the indoor environment.
- All-in-One Solution: Ceiling-mounted AHUs integrate all HVAC components, including fans, coils, filters, and controls, into a single package, simplifying installation and maintenance.
- Energy Efficiency: Many ceiling-mounted AHUs are equipped with energy-efficient components and features, such as variable-speed fans and programmable controls, to minimize energy consumption and reduce operating costs.
- Quiet Operation: Noise reduction features are incorporated into ceiling-mounted AHUs to ensure quiet operation, making them suitable for use in noise-sensitive environments such as offices and conference rooms.
- Flexible Configuration: These units offer flexibility in configuration options, allowing for customization based on specific project requirements, space constraints, and performance criteria.
Applications of Ceiling Mounted AHUs
- Commercial Buildings: Ceiling-mounted AHUs are commonly used in offices, retail stores, restaurants, and other commercial spaces to provide heating, cooling, and ventilation.
- Educational Institutions: These units are installed in schools, colleges, and universities to regulate indoor temperatures and air quality for students and staff.
- Healthcare Facilities: Hospitals, clinics, and medical offices rely on ceiling-mounted AHUs to provide clean and comfortable environments for patient care.
- Hospitality Industry: Hotels, resorts, and other hospitality establishments utilize ceiling-mounted AHUs to ensure guest comfort and satisfaction.
- Residential Buildings: In some cases, ceiling-mounted AHUs are used in residential buildings to provide supplemental heating and cooling in specific rooms or areas.




FAQ
Q: Question:How is your product packaging?
Q: Can you arrange shipment for customers?
Q: If I Place A Large Order, Can I Get A Discount?
Q: Do you accept custom size designs?
Q: Can you print our company's logo on nameplates and packaging?
Hot Tags: roof mounted air handling unit, China roof mounted air handling unit manufacturers, suppliers, factory, appealing items, high quality items, eye-catching items, amazing items, efficient commodities, long lasting products