Overview
Outdoor Air Handling Unit (OAHU) is a specialized type of HVAC equipment designed to treat and condition outdoor air before it is supplied into a building. Unlike conventional air handling units that may circulate indoor air, an OAHU focuses exclusively on processing 100% fresh air from outside. It plays a critical role in maintaining indoor air quality, ensuring sufficient ventilation, and meeting health, safety, and comfort standards across various types of buildings.
Parameter
Cooling, water volume, water resistance
Cooling conditions: Inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃, inlet water temperature 7℃, outlet water temperature 12℃
|
Model |
Two-row pipe |
Four-row pipe |
six-row pipe |
eight-row pipe |
||||||||
|
cooling(KW |
Water volume(m³/h) |
Water resistance (KPa) |
cooling(KW) |
Water volume (m h) |
Water resistance (KPa) |
cooling(kW) |
Water volume (m³/h) |
Water resistance (KPa) |
cooling (KW |
Water volume (m³/h) |
Water resistance (KPa) |
|
|
ZK-05 |
18.8 |
3.23 |
10.1 |
29.4 |
5.01 |
9.76 |
37.8 |
6.49 |
16.99 |
45.7 |
7.85 |
10.44 |
|
ZK-10 |
34.7 |
5.89 |
10.5 |
58.6 |
10.35 |
11.65 |
75.4 |
12.96 |
10.08 |
91.2 |
15.70 |
12.82 |
|
ZK-15 |
53.4 |
9.16 |
9.8 |
87.9 |
15.08 |
7.21 |
113.1 |
19.5 |
12.11 |
136.8 |
23.52 |
15.12 |
|
ZK-20 |
70.6 |
12.14 |
9.8 |
117.3 |
20.16 |
8.25 |
150.8 |
26.21 |
14.07 |
182.4 |
31.96 |
17.48 |
|
ZK-25 |
92.9 |
15.83 |
11.6 |
146.1 |
25.12 |
10.24 |
188.1 |
33.90 |
11.77 |
227.5 |
39.11 |
14.76 |
|
ZK-30 |
113.6 |
19.2 |
11.8 |
175.2 |
30.12 |
11.16 |
225.6 |
38.90 |
13.10 |
273.4 |
47.00 |
16.28 |
|
ZK-40 |
144.4 |
24.82 |
12.4 |
232.8 |
40.03 |
12.93 |
300.2 |
51.61 |
15.73 |
362.2 |
62.27 |
19.20 |
|
ZK-50 |
180.5 |
30.61 |
10.4 |
292.3 |
50.25 |
7.47 |
375.3 |
64.52 |
17.00 |
435.80 |
74.93 |
15.70 |
|
ZK-60 |
216.6 |
37.24 |
9.4 |
349.2 |
60.04 |
7.47 |
450.3 |
77.42 |
17.00 |
544.80 |
93.67 |
15.70 |
|
ZK-80 |
287.2 |
49.1 |
9.1 |
464.6 |
79.88 |
8.5 |
598.4 |
102.89 |
19.5 |
724.8 |
124.62 |
17.9 |
|
ZK-100 |
357.0 |
61.38 |
9.5 |
578.2 |
99.41 |
8.5 |
746.5 |
128.35 |
19.5 |
904.2 |
155.46 |
17.9 |
|
ZK-120 |
428.4 |
73.65 |
9.5 |
693.6 |
118.91 |
8.5 |
895.2 |
153.91 |
19.5 |
1084.8 |
186.51 |
17.9 |
|
ZK-160 |
591.2 |
101.65 |
11.2 |
921.6 |
158.48 |
10.3 |
1190.4 |
204.67 |
20.1 |
1443.2 |
255.93 |
32.4 |
|
ZK-200 |
740.1 |
127.25 |
12.8 |
1152.2 |
199.3 |
13.1 |
1488.1 |
255.86 |
26.4 |
1804.3 |
310.22 |
42.4 |
Note: The performance parameters of the unit at a headwind speed of 2.5m/s
Cooling condition correction factor
|
air temperature |
Water temperature℃ |
|||||
|
Wet bulb Temperature |
Dry bulb Temperature |
5/10 |
6/11 |
7/12 |
8/13 |
9/14 |
|
17 |
19-27 |
0.83 |
0.76 |
0.67 |
0.62 |
0.57 |
|
18 |
20-30 |
0.94 |
1.85 |
0.76 |
0.68 |
0.58 |
|
19 |
21-31 |
1.07 |
0.97 |
0.88 |
0.79 |
0.71 |
|
19.5 |
21-33 |
1.15 |
1.06 |
1.00 |
0.86 |
0.78 |
|
20 |
22-33 |
1.20 |
1.10 |
1.03 |
0.90 |
0.81 |
|
21 |
23-36 |
1.34 |
1.24 |
1.14 |
1.03 |
0.93 |
|
22 |
24-39 |
1.48 |
1.38 |
1.28 |
1.18 |
1.07 |
|
23 |
25-42 |
1.63 |
1.53 |
1.43 |
1.32 |
1.22 |
|
24 |
26-45 |
1.79 |
1.69 |
1.59 |
1.47 |
1.36 |
|
25 |
27-48 |
1.75 |
1.64 |
1.53 |
||
|
26 |
28-48 |
1.92 |
1.81 |
1.70 |
||
|
27 |
29-48 |
2.09 |
1.98 |
1.87 |
||
|
28 |
30-50 |
2.26 |
2.16 |
2.05 |
||
|
29 |
31-52 |
2.40 |
2.32 |
2.2 |
||
Correction Factor K3 for Cooling Capacity and Water Flow under Different Inlet Air and Water Temperatures
|
Headwind speed |
2.0 |
2.3 |
2.5 |
2.7 |
3.0 |
3.3 |
3.5 |
|
coefficient |
0.81 |
0.92 |
1.0 |
1.07 |
1.17 |
1.26 |
1.32 |
|
air temperature |
Water temperature℃ |
|||||
|
Wet bulb Temperature |
Dry bulb Temperature |
5/10 |
6/11 |
7/12 |
8/13 |
9/14 |
|
18 |
20-30 |
0.90 |
0.74 |
0.60 |
0.49 |
0.36 |
|
19 |
21-31 |
1.13 |
0.95 |
0.77 |
0.65 |
0.54 |
|
19.5 |
21-33 |
1.35 |
1.15 |
1.00 |
0.78 |
0.63 |
|
20 |
22-33 |
1.41 |
1.20 |
1.05 |
0.82 |
0.67 |
|
21 |
23-36 |
1.72 |
1.49 |
1.27 |
1.06 |
0.86 |
|
22 |
24-39 |
2.08 |
1.82 |
1.57 |
1.34 |
1.12 |
|
23 |
25-42 |
2.48 |
2.20 |
1.93 |
1.66 |
1.14 |
|
24 |
26-45 |
2.95 |
2.62 |
2.33 |
2.03 |
1.76 |
|
25 |
27-48 |
2.78 |
2.46 |
2.16 |
||
|
26 |
28-48 |
3.30 |
2.94 |
2.60 |
||
|
27 |
29-48 |
3.80 |
3.50 |
3.12 |
||
|
28 |
30-50 |
4.14 |
4.10 |
3.70 |
||
|
29 |
31-52 |
4.14 |
4.10 |
3.70 |
||
Correction Factor K4 for Water Resistance under Different Inlet Air and Water Temperatures
|
Headwind speed |
2.0 |
2.3 |
2.5 |
2.7 |
3.0 |
3.3 |
3.5 |
|
coefficient |
0.9 |
0.96 |
1.0 |
1.04 |
1.1 |
1.16 |
1.2 |
Ps:1.The above correction factors are determined based on the average values of various units. For small units (05~15), multiply by 0.95; for large units (50-200), multiply by 1.08.
2.The above correction factors are approximate values and are for reference only.
Correction under different wind speeds, inlet air temperature, and water temperature conditions:
Actual cooling capacity = Cooling capacity from Table 1 × K1 × K3
Actual water flow = Water flow from Table 1 × K1 × K3
Actual water resistance = Water resistance from Table 1 × K2 × K4
Example: Selecting YG-20 air conditioner, the cooling coil face wind speed is 2.5 m/s. According to Table 1, the cooling capacity is 150.8 kW, water flow is 26.21 m³/h, and water resistance is 14.07 kPa. Determine the actual cooling capacity, water flow, and water resistance when the inlet air dry-bulb temperature is 27°C, wet-bulb temperature is 21°C, inlet water temperature is 7°C, and outlet water temperature is 12°C.
Solution: From Table K1, the correction factor K1 = 1.14. From Table K2, the correction factor K2 = 1.27.
Therefore:
Actual cooling capacity (Q) = Standard condition cooling capacity × K1 = 150.8 × 1.14 = 171.91 kW
Actual water flow (V) = Standard condition water flow × K1 = 26.21 × 1.14 = 29.88 m³/h
Actual water resistance (P) = Standard condition water resistance × K2 = 14.07 × 1.27 = 17.87 kPa
Heating, water volume, water resistance
Heating conditions: air inlet temperature 15℃, water inlet temperature 60℃
|
Model |
Two-row pipe |
four-row pipe |
six-row pipe |
eight-row pipe |
||||||||
|
Heating(KW) |
Water volume (m/h) |
Water resistance (KPa) |
Heating (KW |
Water volume (mh) |
Water resistance (KPa) |
Heating (KW) |
Water volume (m³h) |
Water resistance (KPa) |
Heating(KW) |
Water volume m/h) |
Water resistance (KPa) |
|
|
ZK-05 |
34.1 |
3.23 |
10.1 |
50.6 |
5.01 |
9.76 |
59.2 |
6.49 |
16.99 |
77.1 |
7.85 |
10.44 |
|
ZK-10 |
67.1 |
5.89 |
10.5 |
99.8 |
10.35 |
11.65 |
124.8 |
12.96 |
10.08 |
151.0 |
15.70 |
12.82 |
|
ZK-15 |
101.8 |
9.16 |
9.8 |
149.7 |
15.08 |
7.21 |
173.5 |
19.5 |
12.11 |
205.1 |
23.52 |
15.12 |
|
ZK-20 |
135.6 |
12.14 |
9.8 |
199.0 |
20.16 |
8.25 |
248.8 |
26.21 |
14.07 |
289.3 |
31.96 |
17.48 |
|
ZK-25 |
168.7 |
15.83 |
11.6 |
249.5 |
25.12 |
10.24 |
311.2 |
33.90 |
11.77 |
353.3 |
39.11 |
14.76 |
|
ZK-30 |
202.6 |
19.2 |
11.8 |
304.5 |
30.12 |
11.16 |
380.9 |
38.90 |
13.10 |
448.3 |
47.00 |
16.28 |
|
ZK-40 |
270.4 |
24.82 |
12.4 |
399.2 |
40.03 |
12.93 |
480.8 |
51.61 |
15.73 |
592.4 |
62.27 |
19.20 |
|
ZK-50 |
337.3 |
30.61 |
10.4 |
512.3 |
50.25 |
7.47 |
556.8 |
64.52 |
17.00 |
641.8 |
74.93 |
15.70 |
|
ZK-60 |
404.7 |
37.24 |
9.4 |
609.4 |
60.04 |
7.47 |
581.2 |
77.42 |
17.00 |
766.8 |
93.67 |
15.70 |
|
ZK-80 |
539.5 |
49.1 |
9.1 |
796.0 |
79.88 |
8.5 |
386.2 |
102.89 |
19.5 |
1006.0 |
124.62 |
17.9 |
|
ZK-100 |
674.5 |
61.38 |
9.5 |
985.1 |
99.41 |
8.5 |
1127.6 |
128.35 |
19.5 |
1272.3 |
155.46 |
17.9 |
|
ZK-120 |
808.9 |
73.65 |
9.5 |
1185.9 |
118.91 |
8.5 |
1362.5 |
153.91 |
19.5 |
1533.6 |
186.51 |
17.9 |
|
ZK-160 |
1077.8 |
101.65 |
11.2 |
1576.0 |
158.48 |
10.3 |
1688.4 |
204.67 |
20.1 |
2083.2 |
255.93 |
32.4 |
|
ZK-200 |
1346.2 |
127.25 |
12.8 |
1970.8 |
199.3 |
13.1 |
2032.7 |
255.86 |
26.4 |
2606.2 |
310.22 |
42.4 |
Note: 1. The unit's performance reference at a headwind speed of 2.5m/s
2. The coil is a dual-purpose coil for hot and cold applications
Key Components of an Outdoor Air Handling Unit
●Air Filters: Remove dust, pollen, and airborne contaminants from the incoming air.
●Cooling and Heating Coils: Adjust the air temperature based on seasonal requirements.
●Fans and Blowers: Propel the conditioned air into the building's ventilation network.
●Energy Recovery Systems: Capture heat from exhaust air to pre-treat incoming fresh air, improving energy efficiency.
●Weatherproof Casing: Durable, insulated housing that protects internal components against outdoor weather conditions.
●Control Systems: Modern OAHUs are integrated with smart controllers for monitoring temperature, humidity, CO₂ levels, and equipment performance.
Blower:Blower bearings use lubricated precision ball bearings, and the outer seal ring of the bearing is made of polyamide rubber, which is resistant to high temperatures and can absorb vibration and mechanism noise. The impeller of the purification series air conditioner fan is made of high-quality steel plate (backward-inclined impeller is configured as required), which is more in line with the specific shape of aerodynamics, with high efficiency and low noise.

Surface cooler: The copper tube and aluminum sheet structure is adopted. The copper tube and aluminum sheet are tightly combined by mechanical or water pressure expansion, and tested by 1.6Mpa air pressure to ensure the minimum contact thermal resistance to achieve the best heat transfer effect. The condensate tray is made of high-quality steel plate or SUS304, double-layer filled with polyurethane foam, and the slope design is more conducive to the discharge of condensate, which has obtained the national patent

Filter: Primary, medium and high efficiency filtration sections are equipped with differential pressure gauges to monitor the initial and final resistance of the filter, providing a scientific basis for filter replacement. Primary, medium and high efficiency filters, as well as photohydrogen ion, high voltage electrostatic and electronic purification filters can be configured according to requirements.





FAQ
Q: Do you have testing and auditing services?
Q: What are your shipping services?
Q: What are your delivery terms?
Q: What modes of transportation can you provide?
Q: What is your after-sales service?
Hot Tags: outdoor air handling unit, China outdoor air handling unit manufacturers, suppliers, factory, popular products, well made products, hot commodities, reliable products, trendy items, excellent items